dc.description.abstract

The past two decades have brought an enormous widening of interest in and knowledge about swallowing disorders. The most frequently used technique for swallow evaluation is X-ray videofluoroscopy. Most interventions are based on this examination. Only a few studies assessing interobserver reliability of videofluoroscopy have been published. The aim of our study was to assess the interobserver reliability of videofluoroscopy for swallow evaluation. Fifty-one consecutive dysphagic patients referred for videofluoroscopy were entered into the study regardless of their underlying disorder. The first swallow (5 ml of a semisolid radio-opague contrast media) of each patient was assessed in the lateral projection by 9 independent, experienced observers from different international swallow centers. All studies were evaluated according to a standardized protocol sheet and the interobserver reliability was calculated. The interobserver reliabilities assessed as kappa coefficient for parameters of the oral and pharyngeal phase, for the temporal occurrence of penetration/aspiration, and for the location of bolus residue ranged from 0.01 to 0.56. High reliability with an intraclass coefficient of 0.80 was achieved only with the well defined penetration/aspiration score. Our study underlines the need for exact definitions of the parameters assessed by videofluoroscopy, in order to raise interobserver reliability. To date, only aspiration is evaluated with high reliability by videofluoroscopy, whereas the reliability of all other parameters of oropharyngeal swallow is poor.

dc.identifier.doi10.1007/s00455-002-0085-0
dc.identifier.issn0179-051X
dc.identifier.scopus2-s2.0-0037412273
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/42690
dc.identifier.wos000182592400008
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Interrater reliability of videofluoroscopic swallow evaluation

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleDysphagia
dcterms.bibliographicCitation.number1
dcterms.bibliographicCitation.originalpublishernameSpringer
dcterms.bibliographicCitation.pageend57
dcterms.bibliographicCitation.pagestart53
dcterms.bibliographicCitation.pmid12497197
dcterms.bibliographicCitation.volume18
dspace.entity.typePublicationen
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliationKinderspital Zürich
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationMedical University of South Carolina
uzh.contributor.authorStoeckli, S J
uzh.contributor.authorHuisman, T A G M
uzh.contributor.authorSeifert, Burkhardt
uzh.contributor.authorMartin-Harris, B J W
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitycontent_undefined
uzh.eprint.datestamp2009-06-29 13:26:29
uzh.eprint.lastmod2025-08-02 01:42:36
uzh.eprint.statusChange2009-06-29 13:26:29
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-19457
uzh.jdb.eprintsId12375
uzh.note.publicThe original publication is available at www.springerlink.com
uzh.oastatus.unpaywallclosed
uzh.oastatus.zoraClosed
uzh.publication.citationStoeckli, S J; Huisman, T A G M; Seifert, Burkhardt; Martin-Harris, B J W (2003). Interrater reliability of videofluoroscopic swallow evaluation. Dysphagia, 18(1):53-57.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact170
uzh.scopus.subjectsOtorhinolaryngology
uzh.scopus.subjectsGastroenterology
uzh.scopus.subjectsSpeech and Hearing
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid19457
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions133
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact155
Files

Original bundle

Name:
interrater.pdf
Size:
74.08 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: