Publication:

Estimated Radiation Dose to the Lens During Endourologic Procedures: The Role of Leaded Glasses and the ALARA Protocol-An ESU/ESUT-YAU Endourology Group Collaboration

Date

Date

Date
2023
Journal Article
Published version
cris.lastimport.scopus2025-06-22T03:44:35Z
cris.lastimport.wos2025-07-29T01:30:13Z
dc.contributor.institutionUniversity of Zurich
dc.date.accessioned2023-12-07T08:55:29Z
dc.date.available2023-12-07T08:55:29Z
dc.date.issued2023-08
dc.description.abstract

Purpose: On February 6, 2018, the European Atomic Energy Community reduced the annual equivalent dose limit for the lens from 150 to 20 mSv/year, because of its association with cataracts at low radiation doses. Our aim was to estimate the radiation doses received by the lens during endourologic procedures that require fluoroscopy. Materials and Methods: Multicenter study including prospective data of annual eye dosimeters between 2017 and 2020. Four endourologists used an eye dosimeter in endourologic procedures that require fluoroscopy (ureteroscopy, retrograde intrarenal surgery, and percutaneous nephrolithotomy). Surgeons 1 and 2 wore leaded glasses; surgeon 1 also used the as low as reasonably achievable (ALARA) protocol. Descriptive statistical analysis using SPSS 25.0 was conducted. Results: Surgeons 1, 2, 3, and 4 performed a median of 159, 586, 102, and 129 endourologic procedures per year, respectively, for a total of 641, 2340, 413, and 350 procedures between 2017 and 2020. The median annual dose of lens radiation exposure was 0.16, 1.18, 3.79, and 1.42 mSv per year, respectively, which corresponds to 0.001, 0.009, 0.024, and 0.012 mSv per procedure. The two surgeons who used leaded glasses registered a lower radiation dose per procedure (0.001 vs 0.027). Similarly, the urologist who used the ALARA protocol registered the lowest lens radiation dose compared with the three surgeons who did not use it (0.001 vs 0.023). Conclusions: The endourologists who participated in this study effectively comply with current guidelines on radiation exposure to the lens. Registered eye lens radiation does not seem to be related to the number of procedures but rather to the use of leaded glasses and the ALARA protocol.

dc.identifier.doi10.1089/end.2023.0061
dc.identifier.issn0892-7790
dc.identifier.scopus2-s2.0-85166482161
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/212079
dc.identifier.wos001042987700013
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Estimated Radiation Dose to the Lens During Endourologic Procedures: The Role of Leaded Glasses and the ALARA Protocol-An ESU/ESUT-YAU Endourology Group Collaboration

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleJournal of Endourology
dcterms.bibliographicCitation.number8
dcterms.bibliographicCitation.originalpublishernameMary Ann Liebert
dcterms.bibliographicCitation.pageend939
dcterms.bibliographicCitation.pagestart935
dcterms.bibliographicCitation.pmid37337653
dcterms.bibliographicCitation.volume37
dspace.entity.typePublicationen
uzh.contributor.affiliationUniversitat Autònoma de Barcelona
uzh.contributor.affiliationUniversitat Autònoma de Barcelona
uzh.contributor.affiliationNational and Kapodistrian University of Athens
uzh.contributor.affiliationUniversität Heidelberg
uzh.contributor.affiliationUniversity Hospital Southampton NHS Foundation Trust
uzh.contributor.affiliationHopital Tenon
uzh.contributor.affiliationNational and Kapodistrian University of Athens
uzh.contributor.affiliationHospital de La Santa Creu I Sant Pau
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliationUniversity Hospital Southampton NHS Foundation Trust
uzh.contributor.affiliationIstanbul Üniversitesi Tıp Fakültesi
uzh.contributor.affiliationUniversity Hospital of Ghent
uzh.contributor.affiliationHumanitas Gavazzeni Hospital
uzh.contributor.affiliationUniversity of Patras, School of Medicine
uzh.contributor.affiliationUniversitat Autònoma de Barcelona
uzh.contributor.affiliationUniversitat Autònoma de Barcelona
uzh.contributor.affiliationUniversitat Autònoma de Barcelona
uzh.contributor.authorBravo-Balado, Alejandra
uzh.contributor.authorFontanet, Sofia
uzh.contributor.authorSkolarikos, Andreas
uzh.contributor.authorGozen, Ali Serdar
uzh.contributor.authorSomani, Bhaskar K
uzh.contributor.authorTraxer, Olivier
uzh.contributor.authorPapatsoris, Athanasios
uzh.contributor.authorRuiz Martínez, Agustín
uzh.contributor.authorKeller, Etienne Xavier
uzh.contributor.authorPietropaolo, Amelia
uzh.contributor.authorTonyali, Senol
uzh.contributor.authorTailly, Thomas
uzh.contributor.authorEsperto, Francesco
uzh.contributor.authorLiatsikos, Evangelos
uzh.contributor.authorKanashiro, Andrés K
uzh.contributor.authorAngerri, Oriol
uzh.contributor.authorEmiliani, Esteban
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitynone
uzh.eprint.datestamp2023-12-07 08:55:29
uzh.eprint.lastmod2025-07-29 01:50:37
uzh.eprint.statusChange2023-12-07 08:55:29
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-239500
uzh.jdb.eprintsId10046
uzh.oastatus.unpaywallclosed
uzh.oastatus.zoraClosed
uzh.publication.citationBravo-Balado, A., Fontanet, S., Skolarikos, A., Gozen, A. S., Somani, B. K., Traxer, O., Papatsoris, A., Ruiz Martínez, A., Keller, E. X., Pietropaolo, A., Tonyali, S., Tailly, T., Esperto, F., Liatsikos, E., Kanashiro, A. K., Angerri, O., & Emiliani, E. (2023). Estimated Radiation Dose to the Lens During Endourologic Procedures: The Role of Leaded Glasses and the ALARA Protocol-An ESU/ESUT-YAU Endourology Group Collaboration. Journal of Endourology, 37, 935–939. https://doi.org/10.1089/end.2023.0061
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact1
uzh.scopus.subjectsUrology
uzh.workflow.eprintid239500
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions39
uzh.workflow.rightsCheckkeininfo
uzh.workflow.sourcePubMed:PMID:37337653
uzh.workflow.statusarchive
uzh.wos.impact1
Files

Original bundle

Name:
bravo_balado_et_al_2023_estimated_radiation_dose_to_the_lens_during_endourologic_procedures_the_role_of_leaded_glasses.pdf
Size:
112.34 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: