Publication: Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals
Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals
Date
Date
Date
| cris.lastimport.scopus | 2025-05-19T03:44:19Z | |
| cris.lastimport.wos | 2025-08-17T03:02:30Z | |
| dc.contributor.institution | University of Zurich | |
| dc.date.accessioned | 2018-02-01T13:37:43Z | |
| dc.date.available | 2018-02-01T13:37:43Z | |
| dc.date.issued | 2017-10 | |
| dc.description.abstract | PURPOSE The purpose of this study was to evaluate heat generation at the implant surface caused by abutment preparation using a diamond bur in a high-speed dental turbine in vitro at 2 different water-coolant temperatures. MATERIALS AND METHODS Thirty-two titanium-alloy abutments were connected to a titanium-alloy implant embedded in an acrylic resin placed within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each). Group 1: the temperature was maintained at 20 ± 1°C; and group 2: the temperature was maintained at 32 ± 1°C. Each abutment was prepared in the axial plane for 1 minute and in the occlusal plane for 1 minute. The temperature of the heat generated from abutment preparation was recorded and measured at 3 distinct time intervals. RESULTS Water-coolant temperature (20°C vs 32°C) had a statistically significant effect on the implant's temperature change during preparation of the abutment (P < 0.0001). CONCLUSION The use of water-coolant temperature of 20 ± 1°C during preparation of the implant abutment decreased the temperature recorded at the implant surface to 34.46°C, whereas the coolant temperature of 32 ± 1°C increased the implant surface temperature to 40.94°C. | |
| dc.identifier.doi | 10.1097/ID.0000000000000600 | |
| dc.identifier.issn | 1056-6163 | |
| dc.identifier.scopus | 2-s2.0-85032031808 | |
| dc.identifier.uri | https://www.zora.uzh.ch/handle/20.500.14742/137592 | |
| dc.identifier.wos | 000411682300007 | |
| dc.language.iso | eng | |
| dc.subject.ddc | 610 Medicine & health | |
| dc.title | Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals | |
| dc.type | article | |
| dcterms.accessRights | info:eu-repo/semantics/openAccess | |
| dcterms.bibliographicCitation.journaltitle | Implant Dentistry | |
| dcterms.bibliographicCitation.number | 5 | |
| dcterms.bibliographicCitation.originalpublishername | Lippincott Williams & Wilkins | |
| dcterms.bibliographicCitation.pageend | 705 | |
| dcterms.bibliographicCitation.pagestart | 700 | |
| dcterms.bibliographicCitation.pmid | 28475499 | |
| dcterms.bibliographicCitation.volume | 26 | |
| dspace.entity.type | Publication | en |
| uzh.contributor.affiliation | King Saud Hospital Riyadh | |
| uzh.contributor.affiliation | King Saud University | |
| uzh.contributor.affiliation | Jordan University of Science and Technology | |
| uzh.contributor.affiliation | King Saud University | |
| uzh.contributor.affiliation | National Yang-Ming University Taiwan | |
| uzh.contributor.affiliation | Warwick Medical School | |
| uzh.contributor.affiliation | University of Zurich | |
| uzh.contributor.author | Al-Keraidis, Abdullah | |
| uzh.contributor.author | Aleisa, Khalil | |
| uzh.contributor.author | Al-Dwairi, Ziad Nawaf | |
| uzh.contributor.author | Al-Tahawi, Hamdi | |
| uzh.contributor.author | Hsu, Ming-Lun | |
| uzh.contributor.author | Lynch, Edward | |
| uzh.contributor.author | Özcan, Mutlu | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | Yes | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.document.availability | postprint | |
| uzh.document.availability | published_version | |
| uzh.eprint.datestamp | 2018-02-01 13:37:43 | |
| uzh.eprint.lastmod | 2025-08-17 03:23:37 | |
| uzh.eprint.statusChange | 2018-02-01 13:37:43 | |
| uzh.harvester.eth | Yes | |
| uzh.harvester.nb | No | |
| uzh.identifier.doi | 10.5167/uzh-146146 | |
| uzh.jdb.eprintsId | 13831 | |
| uzh.note.public | For accepted manuscript: This is a non-final version of an article published in final form in Al-Keraidis, Abdullah; Aleisa, Khalil; Al-Dwairi, Ziad Nawaf; Al-Tahawi, Hamdi; Hsu, Ming-Lun; Lynch, Edward; Özcan, Mutlu (2017). Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals. Implant Dentistry, 26(5):700-705. | |
| uzh.oastatus.unpaywall | green | |
| uzh.oastatus.zora | Green | |
| uzh.publication.citation | Al-Keraidis, Abdullah; Aleisa, Khalil; Al-Dwairi, Ziad Nawaf; Al-Tahawi, Hamdi; Hsu, Ming-Lun; Lynch, Edward; Özcan, Mutlu (2017). Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals. Implant Dentistry, 26(5):700-705. | |
| uzh.publication.originalwork | original | |
| uzh.publication.publishedStatus | final | |
| uzh.scopus.impact | 1 | |
| uzh.scopus.subjects | Oral Surgery | |
| uzh.workflow.doaj | uzh.workflow.doaj.false | |
| uzh.workflow.eprintid | 146146 | |
| uzh.workflow.fulltextStatus | public | |
| uzh.workflow.revisions | 58 | |
| uzh.workflow.rightsCheck | keininfo | |
| uzh.workflow.source | PubMed:PMID:28475499 | |
| uzh.workflow.status | archive | |
| uzh.wos.impact | 1 | |
| Files | ||
| Publication available in collections: |