Publication: Direct depiction of bone microstructure using MRI with zero echo time
Direct depiction of bone microstructure using MRI with zero echo time
Date
Date
Date
| cris.lastimport.scopus | 2025-07-27T03:32:28Z | |
| cris.lastimport.wos | 2025-08-09T01:34:37Z | |
| dc.contributor.institution | University of Zurich | |
| dc.date.accessioned | 2013-10-23T07:10:51Z | |
| dc.date.available | 2013-10-23T07:10:51Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | This paper reports a proof of principle of direct depiction of trabecular bone microstructure in vitro by means of magnetic resonance imaging (MRI). Such depiction is achieved by (1)H imaging of water embedded in the bone matrix. The fast transverse relaxation of this compartment with T2(⁎) on the order of a few hundreds of microseconds is addressed by a three-dimensional MRI technique with zero echo time (ZTE). ZTE imaging at an isotropic spatial resolution of 56 μm is demonstrated in a trabecular bone specimen extracted from a bovine bone. In the MR images, the trabecular bone structure is clearly depicted and a high level of robustness against off-resonance artefacts is observed. The structural accuracy of the MR data is investigated by comparison with x-ray micro-computed tomography. | |
| dc.identifier.doi | 10.1016/j.bone.2013.01.027 | |
| dc.identifier.issn | 1873-2763 | |
| dc.identifier.scopus | 2-s2.0-84873724813 | |
| dc.identifier.uri | https://www.zora.uzh.ch/handle/20.500.14742/95069 | |
| dc.identifier.wos | 000316839800006 | |
| dc.language.iso | eng | |
| dc.subject.ddc | 170 Ethics | |
| dc.subject.ddc | 610 Medicine & health | |
| dc.title | Direct depiction of bone microstructure using MRI with zero echo time | |
| dc.type | article | |
| dcterms.accessRights | info:eu-repo/semantics/restrictedAccess | |
| dcterms.bibliographicCitation.journaltitle | Bone | |
| dcterms.bibliographicCitation.number | 1 | |
| dcterms.bibliographicCitation.originalpublishername | Elsevier | |
| dcterms.bibliographicCitation.pageend | 47 | |
| dcterms.bibliographicCitation.pagestart | 44 | |
| dcterms.bibliographicCitation.pmid | 23356986 | |
| dcterms.bibliographicCitation.volume | 54 | |
| dspace.entity.type | Publication | en |
| uzh.contributor.affiliation | Bruker BioSpin, Bruker BioSpin GmbH, Germany, ETH Zürich | |
| uzh.contributor.affiliation | ETH Zürich, Paul Scherrer Institut | |
| uzh.contributor.affiliation | ETH Zürich | |
| uzh.contributor.author | Weiger, Markus | |
| uzh.contributor.author | Stampanoni, Marco | |
| uzh.contributor.author | Pruessmann, Klaas P | |
| uzh.contributor.correspondence | Yes | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.document.availability | none | |
| uzh.eprint.datestamp | 2013-10-23 07:10:51 | |
| uzh.eprint.lastmod | 2025-08-09 01:41:04 | |
| uzh.eprint.statusChange | 2013-10-23 07:10:50 | |
| uzh.harvester.eth | Yes | |
| uzh.harvester.nb | No | |
| uzh.identifier.doi | 10.5167/uzh-82113 | |
| uzh.jdb.eprintsId | 24914 | |
| uzh.oastatus.unpaywall | closed | |
| uzh.oastatus.zora | Closed | |
| uzh.publication.citation | Weiger, M., Stampanoni, M., & Pruessmann, K. P. (2013). Direct depiction of bone microstructure using MRI with zero echo time. Bone, 54, 44–47. https://doi.org/10.1016/j.bone.2013.01.027 | |
| uzh.publication.originalwork | original | |
| uzh.publication.publishedStatus | final | |
| uzh.scopus.impact | 54 | |
| uzh.scopus.subjects | Endocrinology, Diabetes and Metabolism | |
| uzh.scopus.subjects | Physiology | |
| uzh.scopus.subjects | Histology | |
| uzh.workflow.eprintid | 82113 | |
| uzh.workflow.fulltextStatus | restricted | |
| uzh.workflow.revisions | 66 | |
| uzh.workflow.rightsCheck | nichtoffen | |
| uzh.workflow.status | archive | |
| uzh.wos.impact | 50 | |
| Files | Original bundle
Bone_54_1__44_47_Weiger.pdfview file |Download550.36 KB | |
| Publication available in collections: |