dc.description.abstract

This paper reports a proof of principle of direct depiction of trabecular bone microstructure in vitro by means of magnetic resonance imaging (MRI). Such depiction is achieved by (1)H imaging of water embedded in the bone matrix. The fast transverse relaxation of this compartment with T2(⁎) on the order of a few hundreds of microseconds is addressed by a three-dimensional MRI technique with zero echo time (ZTE). ZTE imaging at an isotropic spatial resolution of 56 μm is demonstrated in a trabecular bone specimen extracted from a bovine bone. In the MR images, the trabecular bone structure is clearly depicted and a high level of robustness against off-resonance artefacts is observed. The structural accuracy of the MR data is investigated by comparison with x-ray micro-computed tomography.

dc.identifier.doi10.1016/j.bone.2013.01.027
dc.identifier.issn1873-2763
dc.identifier.scopus2-s2.0-84873724813
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/95069
dc.identifier.wos000316839800006
dc.language.isoeng
dc.subject.ddc170 Ethics
dc.subject.ddc610 Medicine & health
dc.title

Direct depiction of bone microstructure using MRI with zero echo time

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleBone
dcterms.bibliographicCitation.number1
dcterms.bibliographicCitation.originalpublishernameElsevier
dcterms.bibliographicCitation.pageend47
dcterms.bibliographicCitation.pagestart44
dcterms.bibliographicCitation.pmid23356986
dcterms.bibliographicCitation.volume54
dspace.entity.typePublicationen
uzh.contributor.affiliationBruker BioSpin, Bruker BioSpin GmbH, Germany, ETH Zürich
uzh.contributor.affiliationETH Zürich, Paul Scherrer Institut
uzh.contributor.affiliationETH Zürich
uzh.contributor.authorWeiger, Markus
uzh.contributor.authorStampanoni, Marco
uzh.contributor.authorPruessmann, Klaas P
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitynone
uzh.eprint.datestamp2013-10-23 07:10:51
uzh.eprint.lastmod2025-08-09 01:41:04
uzh.eprint.statusChange2013-10-23 07:10:50
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-82113
uzh.jdb.eprintsId24914
uzh.oastatus.unpaywallclosed
uzh.oastatus.zoraClosed
uzh.publication.citationWeiger, M., Stampanoni, M., & Pruessmann, K. P. (2013). Direct depiction of bone microstructure using MRI with zero echo time. Bone, 54, 44–47. https://doi.org/10.1016/j.bone.2013.01.027
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact54
uzh.scopus.subjectsEndocrinology, Diabetes and Metabolism
uzh.scopus.subjectsPhysiology
uzh.scopus.subjectsHistology
uzh.workflow.eprintid82113
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions66
uzh.workflow.rightsChecknichtoffen
uzh.workflow.statusarchive
uzh.wos.impact50
Files

Original bundle

Name:
Bone_54_1__44_47_Weiger.pdf
Size:
550.36 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: