Publication: Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles
Date
Date
Date
Citations
Battmer, R.-D., Dillier, N., Lai, W. K., Begall, K., Leypon, E. E., González, J. C. F., Manrique, M., Morera, C., Müller-Deile, J., Wesarg, T., Zarowski, A., Killian, M. J., von Wallenberg, E., & Smoorenburg, G. F. (2010). Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles. International Journal of Audiology, 49(9), 657–666. https://doi.org/10.3109/14992021003801471
Abstract
Abstract
Abstract
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had lit
Metrics
Downloads
Views
Additional indexing
Creators (Authors)
Volume
Volume
Volume
Number
Number
Number
Page range/Item number
Page range/Item number
Page range/Item number
Page end
Page end
Page end
Item Type
Item Type
Item Type
In collections
Dewey Decimal Classifikation
Dewey Decimal Classifikation
Dewey Decimal Classifikation
Language
Language
Language
Publication date
Publication date
Publication date
Date available
Date available
Date available
ISSN or e-ISSN
ISSN or e-ISSN
ISSN or e-ISSN
OA Status
OA Status
OA Status
Publisher DOI
Metrics
Downloads
Views
Citations
Battmer, R.-D., Dillier, N., Lai, W. K., Begall, K., Leypon, E. E., González, J. C. F., Manrique, M., Morera, C., Müller-Deile, J., Wesarg, T., Zarowski, A., Killian, M. J., von Wallenberg, E., & Smoorenburg, G. F. (2010). Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles. International Journal of Audiology, 49(9), 657–666. https://doi.org/10.3109/14992021003801471