Publication:

Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles

Date

Date

Date
2010
Journal Article
Published version

Citations

Citation copied

Battmer, R.-D., Dillier, N., Lai, W. K., Begall, K., Leypon, E. E., González, J. C. F., Manrique, M., Morera, C., Müller-Deile, J., Wesarg, T., Zarowski, A., Killian, M. J., von Wallenberg, E., & Smoorenburg, G. F. (2010). Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles. International Journal of Audiology, 49(9), 657–666. https://doi.org/10.3109/14992021003801471

Abstract

Abstract

Abstract

Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had lit

Metrics

Downloads

3 since deposited on 2010-12-22
Acq. date: 2025-11-14

Views

119 since deposited on 2010-12-22
Acq. date: 2025-11-14

Additional indexing

Creators (Authors)

  • Battmer, R-D
    affiliation.icon.alt
  • Lai, W K
    affiliation.icon.alt
  • Begall, K
    affiliation.icon.alt
  • Leypon, E E
    affiliation.icon.alt
  • González, J C F
    affiliation.icon.alt
  • Manrique, M
    affiliation.icon.alt
  • Morera, C
    affiliation.icon.alt
  • Müller-Deile, J
    affiliation.icon.alt
  • Wesarg, T
    affiliation.icon.alt
  • Zarowski, A
    affiliation.icon.alt
  • Killian, M J
    affiliation.icon.alt
  • von Wallenberg, E
    affiliation.icon.alt
  • Smoorenburg, G F
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
49

Number

Number

Number
9

Page range/Item number

Page range/Item number

Page range/Item number
657

Page end

Page end

Page end
666

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2010-09

Date available

Date available

Date available
2010-12-22

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
1499-2027

OA Status

OA Status

OA Status
Closed

PubMed ID

PubMed ID

PubMed ID

Metrics

Downloads

3 since deposited on 2010-12-22
Acq. date: 2025-11-14

Views

119 since deposited on 2010-12-22
Acq. date: 2025-11-14

Citations

Citation copied

Battmer, R.-D., Dillier, N., Lai, W. K., Begall, K., Leypon, E. E., González, J. C. F., Manrique, M., Morera, C., Müller-Deile, J., Wesarg, T., Zarowski, A., Killian, M. J., von Wallenberg, E., & Smoorenburg, G. F. (2010). Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear Nucleus CI24RE device: relation to perceptual threshold and loudness comfort profiles. International Journal of Audiology, 49(9), 657–666. https://doi.org/10.3109/14992021003801471

Closed
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image