dc.description.abstract

Objectives: Mandibular functional movements lead to complex deformations of bony structures. The aim of this study was to test whether mandibular splinting influences condylar kinematics and temporomandibular joint (TMJ) loading patterns. Materials and methods: Six subjects were analyzed by means of dynamic stereometry during jaw opening-closing with mandibles unconstrained as well as splinted transversally by a cast metal bar fixed bilaterally to two implant pairs in the (pre)molar region. Statistical analysis was performed by means of ANOVAs for repeated measurements (significance level α=0.05). Results: Transversal splinting reduced mandibular deformation during jaw opening-closing as measured between two implants in the (pre)molar region on each side of the mandible significantly by 54%. Furthermore, splinting significantly reduced the distance between lateral condylar poles (average displacement vector magnitude of each pole: 0.84±0.36 mm; average mediolateral displacement component: 45±28% of the magnitude) and led to a medial displacement of their trajectories as well as a mediolateral displacement of stress-field paths. Conclusions: During jaw opening-closing, splinting of the mandible leads to a significant reduction of mandibular deformation and intercondylar distance and to altered stress-field paths, resulting in changed loading patterns of the TMJ structures. To cite this article: Zaugg B, Hämmerle CHF, Palla S, Gallo LM. Implant-supported mandibular splinting affects temporomandibular joint biomechanics. Clin. Oral Impl. Res. xx, 2011; 000-000. doi: 10.1111/j.1600-0501.2011.02241.x.

dc.identifier.doi10.1111/j.1600-0501.2011.02241.x
dc.identifier.issn0905-7161
dc.identifier.scopus2-s2.0-84863872300
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/66619
dc.identifier.wos000306307700001
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Implant-supported mandibular splinting affects temporomandibular joint biomechanics

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleClinical Oral Implants Research
dcterms.bibliographicCitation.number8
dcterms.bibliographicCitation.originalpublishernameWiley-Blackwell
dcterms.bibliographicCitation.pageend901
dcterms.bibliographicCitation.pagestart897
dcterms.bibliographicCitation.pmid21689164
dcterms.bibliographicCitation.volume23
dspace.entity.typePublicationen
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.authorZaugg, B
uzh.contributor.authorHämmerle, C H F
uzh.contributor.authorPalla, S
uzh.contributor.authorGallo, L M
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceYes
uzh.document.availabilitynone
uzh.eprint.datestamp2012-02-01 11:20:41
uzh.eprint.lastmod2025-08-06 01:58:27
uzh.eprint.statusChange2012-02-01 11:20:41
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-54860
uzh.jdb.eprintsId13311
uzh.oastatus.unpaywallclosed
uzh.oastatus.zoraClosed
uzh.publication.citationZaugg, B; Hämmerle, C H F; Palla, S; Gallo, L M (2012). Implant-supported mandibular splinting affects temporomandibular joint biomechanics. Clinical Oral Implants Research, 23(8):897-901.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact7
uzh.scopus.subjectsOral Surgery
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid54860
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions151
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact7
Files

Original bundle

Name:
2011-COIRPMID21689164.pdf
Size:
564.22 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Name:
Zaugg_et_al_Implant-supported_mandibular_splinting.pdf
Size:
4.63 MB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: