Publication: Marginal discrepancy of monolithic and veneered all-ceramic crowns on titanium and zirconia implant abutments before and after adhesive cementation: a scanning electron microscopy analysis
Marginal discrepancy of monolithic and veneered all-ceramic crowns on titanium and zirconia implant abutments before and after adhesive cementation: a scanning electron microscopy analysis
Date
Date
Date
| cris.lastimport.scopus | 2025-07-29T03:37:09Z | |
| cris.lastimport.wos | 2025-08-10T01:32:57Z | |
| dc.contributor.institution | University of Zurich | |
| dc.date.accessioned | 2014-02-05T09:52:33Z | |
| dc.date.available | 2014-02-05T09:52:33Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | PURPOSE: To evaluate the marginal discrepancy of monolithic and veneered all-ceramic crown systems cemented on titanium (Ti) and zirconia implant abutments. MATERIAL AND METHODS: Sixty customized implant abutments for a maxillary right central incisor were fabricated of Ti and zirconia (n = 30 of each) for an internal-connection implant system. All-ceramic crowns were fabricated using the following systems (n = 10 per group): monolithic with computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate (MLD), pressed lithium disilicate (PLD), or CAD yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP). The frameworks of the PLD and Y-TZP systems were manually veneered with a fluorapatite-based ceramic. The crowns were cemented to their implant abutments, and the absolute marginal discrepancy of the gap was measured before and after cementation. Data were analyzed statistically. RESULTS: Marginal discrepancies were significantly influenced by the crown system and by cementation, but the material did not significantly affect the results. Interaction terms were not significant. Y-TZP crowns on both Ti and zirconia abutments presented the smallest mean marginal discrepancies before (52.1 ± 17 μm and 56.2 ± 11 μm, respectively) and after cementation (98.7 ± 17 μm and 101.8 ± 16 μm, respectively). Before cementation, MLD crowns showed significantly larger mean marginal openings than PLD crowns on both Ti and zirconia abutments (75.2 ± 12 and 77.5 ± 13 μm for MLD, 52.1 ± 17 μm and 69.7 ± 8 μm for PLD, respectively). After cementation, both Ti and zirconia abutments with MLD crowns (113.5 ± 12 μm and 118.3 ± 14 μm, respectively) showed significantly larger values than with PLD crowns (98.7 ± 17 μm and 109.4 ± 9 μm, respectively). CONCLUSIONS: Manually veneered Y-TZP crowns demonstrated more favorable marginal fit on both Ti and zirconia implant abutments before and after cementation compared to those of MLD and PLD. | |
| dc.identifier.doi | 10.11607/jomi.2759 | |
| dc.identifier.issn | 0882-2786 | |
| dc.identifier.scopus | 2-s2.0-84894298908 | |
| dc.identifier.uri | https://www.zora.uzh.ch/handle/20.500.14742/100088 | |
| dc.identifier.wos | 000322077900026 | |
| dc.language.iso | eng | |
| dc.subject.ddc | 610 Medicine & health | |
| dc.title | Marginal discrepancy of monolithic and veneered all-ceramic crowns on titanium and zirconia implant abutments before and after adhesive cementation: a scanning electron microscopy analysis | |
| dc.type | article | |
| dcterms.accessRights | info:eu-repo/semantics/restrictedAccess | |
| dcterms.bibliographicCitation.journaltitle | International Journal of Oral & Maxillofacial Implants | |
| dcterms.bibliographicCitation.number | 2 | |
| dcterms.bibliographicCitation.originalpublishername | Quintessence Publishing | |
| dcterms.bibliographicCitation.pageend | 487 | |
| dcterms.bibliographicCitation.pagestart | 480 | |
| dcterms.bibliographicCitation.pmid | 23527350 | |
| dcterms.bibliographicCitation.volume | 28 | |
| dspace.entity.type | Publication | en |
| uzh.contributor.affiliation | Universidad Complutense de Madrid | |
| uzh.contributor.affiliation | Universidad Complutense de Madrid | |
| uzh.contributor.affiliation | University of Zurich | |
| uzh.contributor.affiliation | Universidad Complutense de Madrid | |
| uzh.contributor.author | Martinez-Rus, Francisco | |
| uzh.contributor.author | Ferreiroa, Alberto | |
| uzh.contributor.author | Özcan, Mutlu | |
| uzh.contributor.author | Pradies, Guillermo | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | Yes | |
| uzh.contributor.correspondence | No | |
| uzh.document.availability | none | |
| uzh.eprint.datestamp | 2014-02-05 09:52:33 | |
| uzh.eprint.lastmod | 2025-08-10 01:54:31 | |
| uzh.eprint.statusChange | 2014-02-05 09:52:33 | |
| uzh.harvester.eth | Yes | |
| uzh.harvester.nb | No | |
| uzh.identifier.doi | 10.5167/uzh-89728 | |
| uzh.jdb.eprintsId | 25702 | |
| uzh.oastatus.unpaywall | closed | |
| uzh.oastatus.zora | Closed | |
| uzh.publication.citation | Martinez-Rus, Francisco; Ferreiroa, Alberto; Özcan, Mutlu; Pradies, Guillermo (2013). Marginal discrepancy of monolithic and veneered all-ceramic crowns on titanium and zirconia implant abutments before and after adhesive cementation: a scanning electron microscopy analysis. International Journal of Oral & Maxillofacial Implants, 28(2):480-487. | |
| uzh.publication.originalwork | original | |
| uzh.publication.publishedStatus | final | |
| uzh.scopus.impact | 44 | |
| uzh.scopus.subjects | Oral Surgery | |
| uzh.workflow.doaj | uzh.workflow.doaj.false | |
| uzh.workflow.eprintid | 89728 | |
| uzh.workflow.fulltextStatus | restricted | |
| uzh.workflow.revisions | 68 | |
| uzh.workflow.rightsCheck | keininfo | |
| uzh.workflow.status | archive | |
| uzh.wos.impact | 40 | |
| Files | Original bundle
Marginal_discrepancy_of_monolithic_and_veneered_acc.pdfview file |Download8.47 MB | |
| Publication available in collections: |