Publication:

Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO

Date

Date

Date
2022
Journal Article
Published version

Citations

Citation copied

Werner-Moller, P., Heinisch, P. P., Hana, A., Bachmann, K. F., Sondergaard, S., Jakob, S. M., Takala, J., & Berger, D. (2022). Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO. Journal of Applied Physiology, 132(3), 726–736. https://doi.org/10.1152/japplphysiol.00804.2021

Abstract

Abstract

Abstract

The mean systemic pressure analog (Pmsa), calculated from running hemodynamic data, estimates mean systemic filling pressure (MSFP). This post hoc study used data from a porcine veno-arterial extracorporeal membrane oxygenation (ECMO) model [n = 9; Sus scrofa domesticus; ES breed (Schweizer Edelschwein)] with eight experimental conditions; Euvolemia [a volume state where ECMO flow produced normal mixed venous saturation (SVO2) without vascular collapse]; three levels of increasing norepinephrine infusion (Vasoconstriction 1-3); status

Metrics

Views

39 since deposited on 2022-10-13
Acq. date: 2025-11-08

Additional indexing

Creators (Authors)

  • Werner-Moller, Per
  • Heinisch, Paul Philipp
  • Hana, Anisa
  • Bachmann, Kaspar F
  • Sondergaard, Soren
  • Jakob, Stephan M
  • Takala, Jukka
  • Berger, David

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
132

Number

Number

Number
3

Page Range

Page Range

Page Range
726

Page end

Page end

Page end
736

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Keywords

Physiology (medical), Physiology

Language

Language

Language
English

Publication date

Publication date

Publication date
2022-03-01

Date available

Date available

Date available
2022-10-13

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
0161-7567

OA Status

OA Status

OA Status
Closed

Free Access at

Free Access at

Free Access at
Unbekannt

PubMed ID

PubMed ID

PubMed ID

Metrics

Views

39 since deposited on 2022-10-13
Acq. date: 2025-11-08

Citations

Citation copied

Werner-Moller, P., Heinisch, P. P., Hana, A., Bachmann, K. F., Sondergaard, S., Jakob, S. M., Takala, J., & Berger, D. (2022). Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO. Journal of Applied Physiology, 132(3), 726–736. https://doi.org/10.1152/japplphysiol.00804.2021

Closed
Loading...
Thumbnail Image

Permanent URL

Permanent URL

Permanent URL
No files available