Diagnostic performance of (18)F-FDG-PET/CT in vascular graft infections


Sah, Bert-Ram; Husmann, Lars; Mayer, Dieter; Scherrer, Alexandra; Rancic, Zoran; Puippe, Gilbert; Weber, Rainer; Hasse, Barbara (2015). Diagnostic performance of (18)F-FDG-PET/CT in vascular graft infections. European Journal of Vascular and Endovascular Surgery, 49(4):455-464.

Abstract

OBJECTIVE The aim of this study was to evaluate the diagnostic accuracy of positron emission tomography/computed tomography with (18)F-fludeoxyglucose (FDG-PET/CT) in a population with suspected graft infection and to validate a new diagnostic imaging score for FDG-PET/CT. METHODS This was a prospective cohort study. FDG-PET/CT was performed prospectively in 34 patients with suspected graft infection, in 12 of them before the start of antimicrobial treatment. Diagnostic accuracy was assessed using a new five point visual grading score and by using a binary score. Maximum standardized uptake values (SUVmax) were calculated for quantitative measurements of metabolic activity, and cut off points were calculated using the receiver operator curve (ROC). The standard of reference was a microbiological culture, obtained after open biopsy or graft explantation. RESULTS Using the new scale, FDG-PET/CT correctly recognized 27 patients with graft infection, one patient was diagnosed as false positive, six patients were correctly classified as true negative, and no patients were rated false negative. Hence, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of FDG-PET/CT for the diagnosis of graft infections were 100%, 86%, 96%, 100%, and 97%, respectively. Using a previously established binary score, sensitivity, specificity, PPV, NPV, and accuracy were 96%, 86%, 96%, 86%, and 94% respectively. ROC analysis suggested an SUVmax cut off value of ≥3.8 to differentiate between infected and non-infected grafts (p < .001). Additionally, FDG-PET/CT provided a conclusive clinical diagnosis in six of seven patients without graft infection (i.e., other sites of infections). CONCLUSIONS The diagnostic accuracy of FDG-PET/CT in the detection of aortic graft infection is high. A newly introduced five point visual grading score and early imaging prior to antimicrobial treatment may further improve the diagnostic accuracy.

Abstract

OBJECTIVE The aim of this study was to evaluate the diagnostic accuracy of positron emission tomography/computed tomography with (18)F-fludeoxyglucose (FDG-PET/CT) in a population with suspected graft infection and to validate a new diagnostic imaging score for FDG-PET/CT. METHODS This was a prospective cohort study. FDG-PET/CT was performed prospectively in 34 patients with suspected graft infection, in 12 of them before the start of antimicrobial treatment. Diagnostic accuracy was assessed using a new five point visual grading score and by using a binary score. Maximum standardized uptake values (SUVmax) were calculated for quantitative measurements of metabolic activity, and cut off points were calculated using the receiver operator curve (ROC). The standard of reference was a microbiological culture, obtained after open biopsy or graft explantation. RESULTS Using the new scale, FDG-PET/CT correctly recognized 27 patients with graft infection, one patient was diagnosed as false positive, six patients were correctly classified as true negative, and no patients were rated false negative. Hence, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of FDG-PET/CT for the diagnosis of graft infections were 100%, 86%, 96%, 100%, and 97%, respectively. Using a previously established binary score, sensitivity, specificity, PPV, NPV, and accuracy were 96%, 86%, 96%, 86%, and 94% respectively. ROC analysis suggested an SUVmax cut off value of ≥3.8 to differentiate between infected and non-infected grafts (p < .001). Additionally, FDG-PET/CT provided a conclusive clinical diagnosis in six of seven patients without graft infection (i.e., other sites of infections). CONCLUSIONS The diagnostic accuracy of FDG-PET/CT in the detection of aortic graft infection is high. A newly introduced five point visual grading score and early imaging prior to antimicrobial treatment may further improve the diagnostic accuracy.

Statistics

Citations

Dimensions.ai Metrics
94 citations in Web of Science®
104 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiac Surgery
04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
04 Faculty of Medicine > University Hospital Zurich > Clinic for Infectious Diseases
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:30 January 2015
Deposited On:26 Feb 2015 07:45
Last Modified:13 Nov 2023 02:41
Publisher:Elsevier
ISSN:1078-5884
OA Status:Closed
Publisher DOI:https://doi.org/10.1016/j.ejvs.2014.12.024
PubMed ID:25648371
Full text not available from this repository.