Comparison of pulmonary artery and transpulmonary thermodilution cardiac output measurements in unsedated newborn calves

Kutter, Annette P N; Jud Schefer, Rahel; Bircher, Barbara; Bleul, Ulrich; Bettschart-Wolfensberger, Regula (2015). Comparison of pulmonary artery and transpulmonary thermodilution cardiac output measurements in unsedated newborn calves. Veterinary Anaesthesia and Analgesia, 42(6):614-622.

Abstract

OBJECTIVE: To compare the agreement, repeatability and trending ability of transpulmonary thermodilution (TPTD) and pulmonary artery thermodilution (PATD) cardiac output (Q˙t) measurements in unsedated newborn calves.
STUDY DESIGN: Prospective experimental trial.
ANIMALS: Eight newborn calves weighing a median (range) of 53 (46-59) kg.
METHODS: Pulmonary and femoral artery thermodilution catheters were placed under local anaesthesia. A total of 382 PATD and TPTD Q˙t measurements were performed simultaneously. Cardiac output was influenced by intravenous doxapram and theophylline in a randomized crossover fashion. Bland-Altman analysis for multiple comparisons, concordance and polar plots were used to assess TPTD against PATD.
RESULTS: Median (range) cardiac index values measured with PATD and TPTD were 197 mL kg(-1) minute(-1) (74-335 mL kg(-1) minute(-1)) and 196 mL kg(-1) minute(-1) (59-395 mL kg(-1) minute(-1)), respectively. A small mean bias of -3 mL kg(-1) minute(-1) with limits of agreement (LOA) of -64 to 58 mL kg(-1) minute(-1) and a percentage error of 31% were found. Eighty-two mean values were calculated. This reduced the LOA to -50 to 41 mL kg(-1) minute(-1) with a similar small bias and a percentage error of 23%. Mean TPTD tracked changes in Q˙t compared with mean PATD with 90% concordance, a mean polar angle of 6° and radial LOA of 43°, indicating marginal trending ability. Keeping the femoral artery catheter patent and obtaining acceptable measurements were very challenging because the calves were not used to being restrained. Calf movement had less influence on PATD.
CONCLUSIONS AND CLINICAL RELEVANCE: We recommend that PATD remains the reference method to measure Q˙t in unsedated newborn calves. However, the robust results of the evaluation of the less invasive TPTD technique warrants further evaluation taking into account the difficulties reported in this study.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Equine Department
05 Vetsuisse Faculty > Veterinary Clinic > Department of Farm Animals
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Scopus Subject Areas:Health Sciences > General Veterinary
Uncontrolled Keywords:calves, cardiac output, monitoring, pulmonary artery thermodilution, transpulmonary thermodilution
Language:English
Date:2015
Deposited On:17 Mar 2015 15:15
Last Modified:13 Sep 2024 01:35
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1467-2987
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/vaa.12243
PubMed ID:25689575