Gunzinger, Jeanne M; Delso, Gaspar; Boss, Andreas; Porto, Miguel; Davison, Helen; von Schulthess, Gustav K; Huellner, Martin; Stolzmann, Paul; Veit-Haibach, Patrick; Burger, Irene A (2014). Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI. EJNMMI Physics, 1(1):102.

Abstract

BACKGROUND: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acquisition variable-resonance image combination (MAVRIC SL) in comparison to conventional high-bandwidth techniques and in a second step showed the effect of artifact size on MRI-based attenuation correction (AC) with a simulation study.
METHODS: Twenty-five patients with dental implants prospectively underwent a trimodality PET/CT/MRI examination after informed consent was obtained under the approval of the local ethics committee. A conventional 3D gradient-echo sequence (LAVA-Flex) commonly used for MRI-based AC of PET (acquisition time of 14 s), a T1w fast spin-echo sequence with high bandwidth (acquisition time of 3.2 min), as well as MAVRIC SL sequence without and with increased phase acceleration (MAVRIC, acquisition time of 6 min; MAVRIC-fast, acquisition time of 3.5 min) were applied. The absolute and relative reduction of the signal void artifact was calculated for each implant and tested for statistical significance using the Wilcoxon signed-rank test. The effect of artifact size on PET AC was simulated in one case with a large tumor in the oral cavity. The relative difference of the maximum standardized uptake value (SUVmax) in the tumor was calculated for increasing artifact sizes centered over the second molar.
RESULTS: The absolute reduction of signal void from LAVA-Flex sequences to the T1-weighted fast spin-echo (FSE) sequences was 416 mm(2) (range 4 to 2,010 mm(2)) to MAVRIC 481 mm(2) (range 12 to 2,288 mm(2)) and to MAVRIC-fast 486 mm(2) (range 39 to 2,209 mm(2)). The relative reduction in signal void was significantly improved for both MAVRIC and MAVRIC-fast compared to T1 FSE (-75%/-78% vs. -62%, p < 0.001 for both). The relative error for SUVmax was negligible for artifacts of 0.5-cm diameter (-0.1%), but substantial for artifacts of 5.2-cm diameter (-33%).
CONCLUSIONS: MAVRIC-fast could become useful for artifact reduction in PET/MR for patients with dental implants. This might improve diagnostic accuracy especially for patients with tumors in the oropharynx and substantially improve accuracy of PET quantification.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Physical Sciences > Radiation
Physical Sciences > Biomedical Engineering
Physical Sciences > Instrumentation
Health Sciences > Radiology, Nuclear Medicine and Imaging
Language:English
Date:December 2014
Deposited On:17 Nov 2015 09:53
Last Modified:09 Aug 2024 03:38
Publisher:SpringerOpen
ISSN:2197-7364
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1186/s40658-014-0102-z
Related URLs:https://www.zora.uzh.ch/id/eprint/117906/
PubMed ID:26501460
Download PDF  'Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution 2.0 Generic (CC BY 2.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Downloads

60 downloads since deposited on 17 Nov 2015
5 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications