Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock

Ganter, Michael T; Alhashemi, Jamal A; Al-Shabasy, Adel M; Schmid, Ursina M; Schott, Peter; Shalabi, Sanaa A; Badri, Ahmed M; Hartnack, Sonja; Hofer, Christoph K (2016). Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock. Journal of Clinical Monitoring and Computing, 30(1):13-22.

Abstract

Septic shock is a serious medical condition. With increased concerns about invasive techniques, a number of non-invasive and semi-invasive devices measuring cardiac output (CO) have become commercially available. The aim of the present study was to determine the accuracy, precision and trending abilities of the FloTrac and the continuous pulmonary artery catheter thermodilution technique determining CO in septic shock patients. Consecutive septic shock patients were included in two centres and CO was measured every 4 h up to 48 h by FloTrac (APCO) and by pulmonary artery catheter (PAC) using the continuous (CCO) and intermittent (ICO) technique. Forty-seven septic shock patients with 326 matched sets of APCO, CCO and ICO data were available for analysis. Bland and Altman analysis revealed a mean bias ±2 SD of 0.0 ± 2.14 L min−1 for APCO–ICO (%error = 34.5 %) and 0.23 ± 2.55 L min−1 for CCO–ICO (%error = 40.4 %). Trend analysis showed a concordance of 85 and 81 % for APCO and CCO, respectively. In contrast to CCO, APCO was influenced by systemic vascular resistance and by mean arterial pressure. In septic shock patients, APCO measurements assessed by FloTrac but also the established CCO measurements using the PAC did not meet the currently accepted statistical criteria indicating acceptable clinical performance.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinärwissenschaftliches Institut > Chair in Veterinary Epidemiology
Dewey Decimal Classification:570 Life sciences; biology
610 Medicine & health
Scopus Subject Areas:Health Sciences > Health Informatics
Health Sciences > Critical Care and Intensive Care Medicine
Health Sciences > Anesthesiology and Pain Medicine
Language:English
Date:2016
Deposited On:25 Feb 2016 14:37
Last Modified:15 Jan 2025 02:36
Publisher:Springer
ISSN:1387-1307
Funders:This study was supported by a grant of Edwards Lifesciences, Irvine, CA, USA
Additional Information:The final publication is available at Springer via http://dx.doi.org/10.1007/s10877-015-9672-0
OA Status:Green
Publisher DOI:https://doi.org/10.1007/s10877-015-9672-0

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
28 citations in Web of Science®
31 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

276 downloads since deposited on 25 Feb 2016
37 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications