Comparison of serum spec fPL(™) and 1,2-o-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6'-Methylresorufin) ester assay in 60 cats using standardized assessment of pancreatic histology

Oppliger, Samuel; Hilbe, Monika; Hartnack, Sonja; Zini, Eric; Reusch, Claudia E; Kook, Peter H (2016). Comparison of serum spec fPL(™) and 1,2-o-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6'-Methylresorufin) ester assay in 60 cats using standardized assessment of pancreatic histology. Journal of Veterinary Internal Medicine, 30(3):764-770.

Abstract

BACKGROUND: Feline pancreas-specific lipase (Spec fPL) is considered a useful test for the antemortem diagnosis of pancreatitis in cats. A recent study found good agreement between the results of the Spec fPL and catalytic 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay. Prospective studies evaluating their sensitivity and specificity are lacking.
OBJECTIVES: To compare the results of the Spec fPL and the DGGR assays with a standardized histologic assessment of the pancreas.
ANIMALS: Sixty client-owned cats presented for necropsy.
METHODS: Prospective study: Spec fPL concentrations and serum DGGR lipase activity were measured from the same blood sample. The pancreas was removed within 3 hours after euthanasia; serial transverse sections were made every 0.5 cm throughout the entire pancreas and reviewed using a histologic grading scheme. Sensitivity and specificity for the Spec fPL and DGGR assay results were determined.
RESULTS: The sensitivity and specificity for the Spec fPL assay (cutoff value ≥5.4 μg/L) was 42.1 [95% confidence interval (95% CI), 29.4-55.9%] and 100% (95% CI, 31.0-100.0%). The sensitivity and specificity for the DGGR assay (cutoff value >26 U/L) was 36.8 (95% CI, 24.7-50.7%) and 100% (95% CI, 31.0-100.0%). When lymphocytic inflammation up to 10% of a section was considered normal, the sensitivity and specificity for Spec fPL assay (cutoff value ≥5.4 μg/L) was 61.1 (95% CI, 36.1-81.7%) and 69.0% (95% CI, 52.8-81.9%) and the sensitivity and specificity for the DGGR assay (cutoff value >26 U/L) was 66.7 (95% CI, 41.2-85.6%) and 78.6% (95% CI, 62.8-89.2%).
CONCLUSIONS AND CLINICAL IMPORTANCE: Both lipase assays performed similarly well, but their agreement with histologic pancreatic inflammation was limited.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinärwissenschaftliches Institut > Institute of Veterinary Pathology
05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals
05 Vetsuisse Faculty > Veterinärwissenschaftliches Institut > Chair in Veterinary Epidemiology
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Scopus Subject Areas:Health Sciences > General Veterinary
Language:English
Date:10 March 2016
Deposited On:31 Mar 2016 19:42
Last Modified:12 Nov 2024 04:41
Publisher:Wiley Open Access
ISSN:0891-6640
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1111/jvim.13924
PubMed ID:26968865
Download PDF  'Comparison of serum spec fPL(™) and 1,2-o-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6'-Methylresorufin) ester assay in 60 cats using standardized assessment of pancreatic histology'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Downloads

78 downloads since deposited on 31 Mar 2016
7 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications