Header

UZH-Logo

Maintenance Infos

Retention force of differently fabricated telescopic PEEK crowns with different tapers


Stock, Veronika; Wagner, Christina; Merk, Susanne; Roos, Malgorzata; Schmidlin, Patrick R; Eichberger, Marlis; Stawarczyk, Bogna (2016). Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dental Materials Journal, 35(4):594-600.

Abstract

To assess the retention force between primary and secondary PEEK crowns made by different fabrication methods. Primary crowns with different tapers (0°, 1°, and 2°) were fabricated and secondary crowns that were either milled from breCam BioHPP blanks, pressed from pellets (BioHPP Pellet) or granules (BioHPP Granulat) were produced. Each specimen was measured 20 times in a pulloff-test and results were analyzed using 2-/1-way ANOVA and linear regression analyses (p<0.05). Within 0° tapered crowns milled secondary crowns showed lower retention forces compared to pressed pellet crowns. Crowns with a 1° taper, however, showed no impact of the fabrication method on retention force. At a 2° taper, granular pressed crowns displayed lower values than their milled counterparts. Within the milled group, a 0° taper showed lower retention values than the higher tapers, whereas in the pressed groups, no impact of taper angle on retention force was found.

Abstract

To assess the retention force between primary and secondary PEEK crowns made by different fabrication methods. Primary crowns with different tapers (0°, 1°, and 2°) were fabricated and secondary crowns that were either milled from breCam BioHPP blanks, pressed from pellets (BioHPP Pellet) or granules (BioHPP Granulat) were produced. Each specimen was measured 20 times in a pulloff-test and results were analyzed using 2-/1-way ANOVA and linear regression analyses (p<0.05). Within 0° tapered crowns milled secondary crowns showed lower retention forces compared to pressed pellet crowns. Crowns with a 1° taper, however, showed no impact of the fabrication method on retention force. At a 2° taper, granular pressed crowns displayed lower values than their milled counterparts. Within the milled group, a 0° taper showed lower retention values than the higher tapers, whereas in the pressed groups, no impact of taper angle on retention force was found.

Statistics

Citations

Dimensions.ai Metrics
25 citations in Web of Science®
25 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

15 downloads since deposited on 18 Oct 2016
9 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
04 Faculty of Medicine > Center for Dental Medicine > Clinic of Conservative and Preventive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Physical Sciences > Ceramics and Composites
Health Sciences > General Dentistry
Language:English
Date:2016
Deposited On:18 Oct 2016 12:55
Last Modified:08 Jul 2022 12:59
Publisher:Japanese Society for Dental Materials and Devices
ISSN:0287-4547
OA Status:Gold
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.4012/dmj.2015-249
PubMed ID:27477224
  • Content: Published Version
  • Language: English
  • Content: Accepted Version
  • Language: English