Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Benz, Dominik C; Gräni, Christoph; Ferro, Paola; Neumeier, Luis; Messerli, Michael; Possner, Mathias; Clerc, Olivier F; Gebhard, Catherine; Gaemperli, Oliver; Pazhenkottil, Aju P; Kaufmann, Philipp A; Buechel, Ronny R (2019). Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography. Journal of Nuclear Cardiology, 26(2):561-568.

Abstract

BACKGROUND: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI).
METHODS AND RESULTS: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively.
CONCLUSIONS: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Health Sciences > Cardiology and Cardiovascular Medicine
Uncontrolled Keywords:Corrected coronary opacification, quantitative PET myocardial perfusion imaging, relative flow reserve
Language:English
Date:April 2019
Deposited On:02 Aug 2017 15:59
Last Modified:17 Dec 2024 02:36
Publisher:Springer
ISSN:1071-3581
OA Status:Closed
Publisher DOI:https://doi.org/10.1007/s12350-017-0980-2
PubMed ID:28685251

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
13 citations in Web of Science®
12 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 02 Aug 2017
0 downloads since 12 months

Authors, Affiliations, Collaborations