ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations


Ehrbar, Stefanie; Jöhl, Alexander; Tartas, Adrianna; Stark, Luisa Sabrina; Riesterer, Oliver; Klöck, Stephan; Guckenberger, Matthias; Tanadini-Lang, Stephanie (2017). ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations. Radiotherapy and Oncology, 124(1):80-88.

Abstract

PURPOSE: Respiratory motion-management techniques (MMT) aim to ensure tumor dose coverage while sparing lung tissue. Dynamic treatment-couch tracking of the moving tumor is a promising new MMT and was compared to the internal-target-volume (ITV) concept, the mid-ventilation (MidV) principle and the gating approach in a planning study based on 4D dose calculations.
METHODS: For twenty patients with lung lesions, planning target volumes (PTV) were adapted to the MMT and stereotactic body radiotherapy treatments were prepared with the 65%-isodose enclosing the PTV. For tracking, three concepts for target volume definition were considered: Including the gross tumor volume of one phase (single-phase tracking), including deformations between phases (multi-phase tracking) and additionally including tracking latencies of a couch tracking system (reliable couch tracking). The accumulated tumor and lung doses were estimated with 4D dose calculations based on 4D-CT datasets and deformable image registration.
RESULTS: Single-phase tracking showed the lowest ipsilateral lung Dmean (median: 3.3Gy), followed by multi-phase tracking, gating, reliable couch tracking, MidV and ITV concepts (3.6, 3.8, 4.1, 4.3 and 4.8Gy). The 4D dose calculations showed the MidV and single-phase tracking overestimated the target mean dose (-2.3% and -1.3%), while it was slightly underestimated by the other MMT (<+1%).
CONCLUSION: The ITV concept ensures tumor coverage, but exposes the lung tissue to a higher dose. The MidV, gating and tracking concepts were shown to reduce the lung dose. Neglecting non-translational changes of the tumor in the target volume definition for tracking results in a slightly reduced target coverage. The slightly inferior dose coverage for MidV should be considered when applying this technique clinically.

Abstract

PURPOSE: Respiratory motion-management techniques (MMT) aim to ensure tumor dose coverage while sparing lung tissue. Dynamic treatment-couch tracking of the moving tumor is a promising new MMT and was compared to the internal-target-volume (ITV) concept, the mid-ventilation (MidV) principle and the gating approach in a planning study based on 4D dose calculations.
METHODS: For twenty patients with lung lesions, planning target volumes (PTV) were adapted to the MMT and stereotactic body radiotherapy treatments were prepared with the 65%-isodose enclosing the PTV. For tracking, three concepts for target volume definition were considered: Including the gross tumor volume of one phase (single-phase tracking), including deformations between phases (multi-phase tracking) and additionally including tracking latencies of a couch tracking system (reliable couch tracking). The accumulated tumor and lung doses were estimated with 4D dose calculations based on 4D-CT datasets and deformable image registration.
RESULTS: Single-phase tracking showed the lowest ipsilateral lung Dmean (median: 3.3Gy), followed by multi-phase tracking, gating, reliable couch tracking, MidV and ITV concepts (3.6, 3.8, 4.1, 4.3 and 4.8Gy). The 4D dose calculations showed the MidV and single-phase tracking overestimated the target mean dose (-2.3% and -1.3%), while it was slightly underestimated by the other MMT (<+1%).
CONCLUSION: The ITV concept ensures tumor coverage, but exposes the lung tissue to a higher dose. The MidV, gating and tracking concepts were shown to reduce the lung dose. Neglecting non-translational changes of the tumor in the target volume definition for tracking results in a slightly reduced target coverage. The slightly inferior dose coverage for MidV should be considered when applying this technique clinically.

Statistics

Citations

Dimensions.ai Metrics
31 citations in Web of Science®
27 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

157 downloads since deposited on 16 Nov 2017
77 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Radiation Oncology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Hematology
Health Sciences > Oncology
Health Sciences > Radiology, Nuclear Medicine and Imaging
Uncontrolled Keywords:Oncology, Radiology Nuclear Medicine and imaging, Hematology
Language:English
Date:July 2017
Deposited On:16 Nov 2017 15:32
Last Modified:28 Jul 2020 11:52
Publisher:Elsevier
ISSN:0167-8140
OA Status:Green
Publisher DOI:https://doi.org/10.1016/j.radonc.2017.05.016
PubMed ID:28587761
Project Information:
  • : FunderSNSF
  • : Grant IDCR32I3_153491
  • : Project TitleDevelopment of prediction models for liver, lung and breast tumors and implementation and verification of prediction filters for advanced couch tracking in a clinical environment

Download

Green Open Access

Download PDF  'ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations'.
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher
Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)