Header

UZH-Logo

Maintenance Infos

Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating


Husmann, L; Herzog, B A; Gaemperli, O; Tatsugami, F; Burkhard, N; Valenta, I; Veit-Haibach, P; Wyss, M T; Landmesser, U; Kaufmann, P A (2009). Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating. European Heart Journal, 30(5):600-607.

Abstract

Aims To determine diagnostic accuracy, effective radiation dose, and potential value of computed tomography coronary angiography (CTCA) for hybrid imaging with single-photon emission computed tomography (SPECT) comparing prospective electrocardiogram (ECG)-triggering vs. retrospective ECG-gating. Methods and results Two hundred patients underwent standard myocardial stress/rest- SPECT perfusion imaging, which served as standard of reference. One hundred consecutive patients underwent 64-slice CTCA using prospective ECG-gating, and were compared with 100 patients who had previously undergone CTCA using retrospective ECG-gating. For predicting ischaemia, CTCA with prospective ECG-triggering and a stenosis cut-off >50% had a per-vessel sensitivity, specificity, negative, and positive predictive value of 100, 84, 100, and 30%; respective values for CTCA with retrospective ECG-gating were similar (P = n.s.): 86, 83, 98, and 33%. Combining CTCA with stress-only SPECT revealed 100% clinical agreement with regard to perfusion defects, and provided additional information in half the patients on preclinical coronary findings. Effective radiation dose was 2.2 +/- 0.7 mSv for CTCA with prospective ECG-triggering, and 19.7 +/- 4.2 mSv with retrospective ECG-gating (P < 0.001) (5.4 +/- 0.8 vs. 24.1 +/- 4.3 mSv for hybrid imaging). Conclusion Prospective ECG-triggering for CTCA reduces radiation dose by almost 90% without affecting diagnostic performance. Combined imaging with stress-only SPECT is an attractive alternative to standard stress/rest-SPECT for evaluation of coronary artery disease, offering additional information on preclinical atherosclerosis.

Abstract

Aims To determine diagnostic accuracy, effective radiation dose, and potential value of computed tomography coronary angiography (CTCA) for hybrid imaging with single-photon emission computed tomography (SPECT) comparing prospective electrocardiogram (ECG)-triggering vs. retrospective ECG-gating. Methods and results Two hundred patients underwent standard myocardial stress/rest- SPECT perfusion imaging, which served as standard of reference. One hundred consecutive patients underwent 64-slice CTCA using prospective ECG-gating, and were compared with 100 patients who had previously undergone CTCA using retrospective ECG-gating. For predicting ischaemia, CTCA with prospective ECG-triggering and a stenosis cut-off >50% had a per-vessel sensitivity, specificity, negative, and positive predictive value of 100, 84, 100, and 30%; respective values for CTCA with retrospective ECG-gating were similar (P = n.s.): 86, 83, 98, and 33%. Combining CTCA with stress-only SPECT revealed 100% clinical agreement with regard to perfusion defects, and provided additional information in half the patients on preclinical coronary findings. Effective radiation dose was 2.2 +/- 0.7 mSv for CTCA with prospective ECG-triggering, and 19.7 +/- 4.2 mSv with retrospective ECG-gating (P < 0.001) (5.4 +/- 0.8 vs. 24.1 +/- 4.3 mSv for hybrid imaging). Conclusion Prospective ECG-triggering for CTCA reduces radiation dose by almost 90% without affecting diagnostic performance. Combined imaging with stress-only SPECT is an attractive alternative to standard stress/rest-SPECT for evaluation of coronary artery disease, offering additional information on preclinical atherosclerosis.

Statistics

Citations

Dimensions.ai Metrics
84 citations in Web of Science®
84 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

324 downloads since deposited on 26 Feb 2009
16 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:23 March 2009
Deposited On:26 Feb 2009 09:00
Last Modified:02 Oct 2023 01:50
Publisher:Oxford University Press
ISSN:0195-668X
Additional Information:This is a pre-copy-editing, author-produced PDF of an article accepted for publication in European Heart Journal following peer review. The definitive publisher-authenticated version European Heart Journal 2009 30(5):600-607; doi:10.1093/eurheartj/ehn536 is available online at: http://eurheartj.oxfordjournals.org/cgi/content/abstract/30/5/600
OA Status:Hybrid
Publisher DOI:https://doi.org/10.1093/eurheartj/ehn536
PubMed ID:19106197
  • Content: Published Version
  • Language: English
  • Description: Nationallizenz 142-005
  • Content: Accepted Version
  • Language: English