Header

UZH-Logo

Maintenance Infos

Genotoxic potential of dental bulk-fill resin composites


Tauböck, Tobias T; Marovic, Danijela; Zeljezic, Davor; Steingruber, Andrea D; Attin, Thomas; Tarle, Zrinka (2017). Genotoxic potential of dental bulk-fill resin composites. Dental Materials, 33(7):788-795.

Abstract

OBJECTIVE: To investigate both genotoxicity and hardening of bulk-fill composite materials applied in 4-mm layer thickness and photo-activated for different exposure times. METHODS: Three flowable bulk-fill materials and one conventional flowable composite were filled in molds (height: 4mm) and irradiated for 20 or 30s. The top (0mm) and bottom (4mm) specimen surface were mechanically scraped, and eluates (0.01g composite in 1.5ml RPMI 1640 cell culture media) prepared for each material, surface level and irradiation time. Genotoxicity was assessed in human leukocytes using both the alkaline comet assay and cytokinesis-blocked micronucleus assay, and Knoop hardness (KHN) was measured at the top and bottom specimen surface (n=8). RESULTS: At both irradiation times, none of the bulk-fill composites significantly affected comet assay parameters used in primary DNA damage assessment or induced significant formation of any of the scored chromatin abnormalities (number of micronuclei, nuclear buds, nucleoplasmic bridges), whether eluates were obtained from the top or bottom surface. Furthermore, no decrease in KHN from the top to the bottom surface of the bulk-fill materials was observed. On the other hand, the conventional composite irradiated for 20s showed at 4-mm depth a significant increase in the percentage of DNA that migrated in the tail and a significant increase in the number of nuclear buds, as well as a significant decrease in KHN relative to the top surface. SIGNIFICANCE: Bulk-fill resin composites, in contrast to conventional composite, applied in 4-mm thickness and photo-activated for at least 20s do not induce relevant genotoxic effects or mechanical instability.

Abstract

OBJECTIVE: To investigate both genotoxicity and hardening of bulk-fill composite materials applied in 4-mm layer thickness and photo-activated for different exposure times. METHODS: Three flowable bulk-fill materials and one conventional flowable composite were filled in molds (height: 4mm) and irradiated for 20 or 30s. The top (0mm) and bottom (4mm) specimen surface were mechanically scraped, and eluates (0.01g composite in 1.5ml RPMI 1640 cell culture media) prepared for each material, surface level and irradiation time. Genotoxicity was assessed in human leukocytes using both the alkaline comet assay and cytokinesis-blocked micronucleus assay, and Knoop hardness (KHN) was measured at the top and bottom specimen surface (n=8). RESULTS: At both irradiation times, none of the bulk-fill composites significantly affected comet assay parameters used in primary DNA damage assessment or induced significant formation of any of the scored chromatin abnormalities (number of micronuclei, nuclear buds, nucleoplasmic bridges), whether eluates were obtained from the top or bottom surface. Furthermore, no decrease in KHN from the top to the bottom surface of the bulk-fill materials was observed. On the other hand, the conventional composite irradiated for 20s showed at 4-mm depth a significant increase in the percentage of DNA that migrated in the tail and a significant increase in the number of nuclear buds, as well as a significant decrease in KHN relative to the top surface. SIGNIFICANCE: Bulk-fill resin composites, in contrast to conventional composite, applied in 4-mm thickness and photo-activated for at least 20s do not induce relevant genotoxic effects or mechanical instability.

Statistics

Citations

Dimensions.ai Metrics
29 citations in Web of Science®
27 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

244 downloads since deposited on 12 Jan 2018
45 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Conservative and Preventive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Physical Sciences > General Materials Science
Health Sciences > General Dentistry
Physical Sciences > Mechanics of Materials
Language:English
Date:July 2017
Deposited On:12 Jan 2018 11:59
Last Modified:26 Feb 2023 08:01
Publisher:Elsevier
ISSN:0109-5641
OA Status:Green
Publisher DOI:https://doi.org/10.1016/j.dental.2017.04.011
PubMed ID:28535953
  • Content: Accepted Version
  • Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)