OBJECTIVE: To investigate both genotoxicity and hardening of bulk-fill composite materials applied in 4-mm layer thickness and photo-activated for different exposure times. METHODS: Three flowable bulk-fill materials and one conventional flowable composite were filled in molds (height: 4mm) and irradiated for 20 or 30s. The top (0mm) and bottom (4mm) specimen surface were mechanically scraped, and eluates (0.01g composite in 1.5ml RPMI 1640 cell culture media) prepared for each material, surface level and irradiation time. Genotoxicity was assessed in human leukocytes using both the alkaline comet assay and cytokinesis-blocked micronucleus assay, and Knoop hardness (KHN) was measured at the top and bottom specimen surface (n=8). RESULTS: At both irradiation times, none of the bulk-fill composites significantly affected comet assay parameters used in primary DNA damage assessment or induced significant formation of any of the scored chromatin abnormalities (number of micronuclei, nuclear buds, nucleoplasmic bridges), whether eluates were obtained from the top or bottom surface. Furthermore, no decrease in KHN from the top to the bottom surface of the bulk-fill materials was observed. On the other hand, the conventional composite irradiated for 20s showed at 4-mm depth a significant increase in the percentage of DNA that migrated in the tail and a significant increase in the number of nuclear buds, as well as a significant decrease in KHN relative to the top surface. SIGNIFICANCE: Bulk-fill resin composites, in contrast to conventional composite, applied in 4-mm thickness and photo-activated for at least 20s do not induce relevant genotoxic effects or mechanical instability.

Abstract

OBJECTIVE: To investigate both genotoxicity and hardening of bulk-fill composite materials applied in 4-mm layer thickness and photo-activated for different exposure times. METHODS: Three flowable bulk-fill materials and one conventional flowable composite were filled in molds (height: 4mm) and irradiated for 20 or 30s. The top (0mm) and bottom (4mm) specimen surface were mechanically scraped, and eluates (0.01g composite in 1.5ml RPMI 1640 cell culture media) prepared for each material, surface level and irradiation time. Genotoxicity was assessed in human leukocytes using both the alkaline comet assay and cytokinesis-blocked micronucleus assay, and Knoop hardness (KHN) was measured at the top and bottom specimen surface (n=8). RESULTS: At both irradiation times, none of the bulk-fill composites significantly affected comet assay parameters used in primary DNA damage assessment or induced significant formation of any of the scored chromatin abnormalities (number of micronuclei, nuclear buds, nucleoplasmic bridges), whether eluates were obtained from the top or bottom surface. Furthermore, no decrease in KHN from the top to the bottom surface of the bulk-fill materials was observed. On the other hand, the conventional composite irradiated for 20s showed at 4-mm depth a significant increase in the percentage of DNA that migrated in the tail and a significant increase in the number of nuclear buds, as well as a significant decrease in KHN relative to the top surface. SIGNIFICANCE: Bulk-fill resin composites, in contrast to conventional composite, applied in 4-mm thickness and photo-activated for at least 20s do not induce relevant genotoxic effects or mechanical instability.

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Downloads

9 downloads since deposited on 12 Jan 2018
9 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Preventive Dentistry, Periodontology and Cariology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:July 2017
Deposited On:12 Jan 2018 11:59
Last Modified:20 May 2018 00:00
Publisher:Elsevier
ISSN:0109-5641
OA Status:Green
Publisher DOI:https://doi.org/10.1016/j.dental.2017.04.011
PubMed ID:28535953

Download

Download PDF  'Genotoxic potential of dental bulk-fill resin composites'.
Preview
Content: Accepted Version
Filetype: PDF
Size: 227kB
View at publisher
Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)