Obesity is a global health threat on the rise, and its prevalence continues to grow. Yet suitable biomedical sensors to monitor body fat burn rates in situ, to guide physical activity or dietary interventions toward efficient weight loss, are missing. Here, we introduce a compact and inexpensive breath acetone sensor based on Si-doped WO3 nanoparticles that can accurately follow body fat burn rates in real time. We tested this sensor on 20 volunteers during exercise and rest and measured their individual breath acetone concentrations in good agreement with benchtop proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS). During exercise, this sensor reveals clearly the onset and progression of increasing breath acetone levels that indicate intensified body fat metabolism, as validated by parallel venous blood β-hydroxybutyrate (BOHB) measurements. Most importantly, we found that the body fat metabolism was especially pronounced for most volunteers during fasting for 3 h after exercise, with strong variation between subjects, and this was displayed correctly by the sensor in real-time. As a result, this simple breath acetone sensor enables easily applicable and hand-held body fat burn monitoring for personalized and immediate feedback on workout effectiveness that can guide dieting as well.

Abstract

Obesity is a global health threat on the rise, and its prevalence continues to grow. Yet suitable biomedical sensors to monitor body fat burn rates in situ, to guide physical activity or dietary interventions toward efficient weight loss, are missing. Here, we introduce a compact and inexpensive breath acetone sensor based on Si-doped WO3 nanoparticles that can accurately follow body fat burn rates in real time. We tested this sensor on 20 volunteers during exercise and rest and measured their individual breath acetone concentrations in good agreement with benchtop proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS). During exercise, this sensor reveals clearly the onset and progression of increasing breath acetone levels that indicate intensified body fat metabolism, as validated by parallel venous blood β-hydroxybutyrate (BOHB) measurements. Most importantly, we found that the body fat metabolism was especially pronounced for most volunteers during fasting for 3 h after exercise, with strong variation between subjects, and this was displayed correctly by the sensor in real-time. As a result, this simple breath acetone sensor enables easily applicable and hand-held body fat burn monitoring for personalized and immediate feedback on workout effectiveness that can guide dieting as well.

Statistics

Citations

Dimensions.ai Metrics
12 citations in Web of Science®
13 citations in Scopus®
6 citations in Microsoft Academic
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Pneumology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:3 October 2017
Deposited On:23 Jan 2018 13:37
Last Modified:19 Feb 2018 10:35
Publisher:American Chemical Society (ACS)
ISSN:0003-2700
OA Status:Closed
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1021/acs.analchem.7b02843
PubMed ID:28891296

Download

Full text not available from this repository.
View at publisher

Get full-text in a library