Header

UZH-Logo

Maintenance Infos

Alternative inert gas washout outcomes in patients with primary ciliary dyskinesia


Nyilas, Sylvia; Schlegtendal, Anne; Singer, Florian; Goutaki, Myrofora; Kuehni, Claudia E; Casaulta, Carmen; Latzin, Philipp; Koerner-Rettberg, Cordula (2017). Alternative inert gas washout outcomes in patients with primary ciliary dyskinesia. European Respiratory Journal, 49(1):1600466.

Abstract

The lung clearance index (LCI) derived from a nitrogen multiple breath washout test (N2-MBW) is a promising tool to assess small airways disease in primary ciliary dyskinesia, but it is difficult to apply in routine clinical settings because of its long measuring time. In this study, we aimed to assess alternative indices derived from shorter washout protocols.49 patients with primary ciliary dyskinesia (mean age 14.7±6.6 years) and 37 controls (mean age 14.3±1.4 years) performed N2-MBW and double-tracer gas (DTG) single-breath washout tests. Global (LCI and moment ratio (M2/M0)), conductive (Scond) and acinar ventilation inhomogeneity (DTG Slope III (SIII-DTG)) were determined for each individual. The main outcomes were 1) the ability to detect abnormal lung function from washout indices (>1.64 z-scores) and 2) measurement duration.The prevalence of abnormal values for LCI2.5% was 37 out of 47 (79%), for LCI5% was 34 out of 47 (72%), for M2/M0 was 34 out of 47 (72%), for Scond was 36 out of 46 (78%) and for SIII-DTG was 12 out of 35 (34%). Mean±sd duration of measurement was 19.8±11.2 min for LCI2.5%, 10.8±4.6 min for LCI5% and 8.6±2.3 min for ScondCompared to standard LCI2.5%, ventilation inhomogeneity was detected by LCI5%, moment ratio and Scond with comparable sensitivity while measurement duration was significantly shorter. Longitudinal studies will show which outcome is most suitable and practical in terms of sensitivity, duration and variability within the course of primary ciliary dyskinesia lung disease.

Abstract

The lung clearance index (LCI) derived from a nitrogen multiple breath washout test (N2-MBW) is a promising tool to assess small airways disease in primary ciliary dyskinesia, but it is difficult to apply in routine clinical settings because of its long measuring time. In this study, we aimed to assess alternative indices derived from shorter washout protocols.49 patients with primary ciliary dyskinesia (mean age 14.7±6.6 years) and 37 controls (mean age 14.3±1.4 years) performed N2-MBW and double-tracer gas (DTG) single-breath washout tests. Global (LCI and moment ratio (M2/M0)), conductive (Scond) and acinar ventilation inhomogeneity (DTG Slope III (SIII-DTG)) were determined for each individual. The main outcomes were 1) the ability to detect abnormal lung function from washout indices (>1.64 z-scores) and 2) measurement duration.The prevalence of abnormal values for LCI2.5% was 37 out of 47 (79%), for LCI5% was 34 out of 47 (72%), for M2/M0 was 34 out of 47 (72%), for Scond was 36 out of 46 (78%) and for SIII-DTG was 12 out of 35 (34%). Mean±sd duration of measurement was 19.8±11.2 min for LCI2.5%, 10.8±4.6 min for LCI5% and 8.6±2.3 min for ScondCompared to standard LCI2.5%, ventilation inhomogeneity was detected by LCI5%, moment ratio and Scond with comparable sensitivity while measurement duration was significantly shorter. Longitudinal studies will show which outcome is most suitable and practical in terms of sensitivity, duration and variability within the course of primary ciliary dyskinesia lung disease.

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
4 citations in Scopus®
3 citations in Microsoft Academic
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:25 January 2017
Deposited On:07 Feb 2018 07:39
Last Modified:19 Feb 2018 10:52
Publisher:European Respiratory Society
ISSN:0903-1936
OA Status:Closed
Publisher DOI:https://doi.org/10.1183/13993003.00466-2016
PubMed ID:28122863

Download

Full text not available from this repository.
View at publisher

Get full-text in a library