Header

UZH-Logo

Maintenance Infos

Viscoelastic properties of orthodontic adhesives used for lingual fixed retainer bonding


Papadogiannis, Dimitris; Iliadi, Anna; Bradley, T Gerard; Silikas, Nikolaos; Eliades, George; Eliades, Theodore (2017). Viscoelastic properties of orthodontic adhesives used for lingual fixed retainer bonding. Dental Materials, 33(1):e22-e27.

Abstract

OBJECTIVE: To evaluate the viscoelastic properties of two experimental BPA-free and one BisGMA-based orthodontic resin composite adhesives for bonding fixed retainers.
METHODS: A commercially available BisGMA-based (TXA: Transbond LR) and two bisphenol A-free experimental adhesives (EXA and EXB) were included in the study. The viscoelastic behavior of the adhesives was evaluated under static and dynamic conditions at dry and wet states and at various temperatures (21, 37, 50°C). The parameters determined were shear modulus (G), Young's modulus (E) under static testing and storage modulus (G1), loss tangent (tanδ) and dynamic viscosity (n*) under dynamic testing. Statistical analysis was performed by 2-way ANOVA and Bonferroni post-hoc tests (α=0.05).
RESULTS: For static testing, a significant difference was found within material and storage condition variables and a significant interaction between the two independent variables (p<0.001 for G and E). EXA demonstrated the highest G and E values at 21°C/dry group. Dry specimens showed the highest G and E values, but with no significant difference from 21°C/wet specimens, except EXA in G. Wet storage at higher temperatures (37°C and 50°C) adversely affected all the materials to a degree ranging from 40 to 60% (p<0.001). For dynamic testing, a significant difference was also found in material and testing condition groups, with a significant interaction between the two independent variables (p<0.001 for G1 and n*, p<0.01 for tanδ). Reduction in G1, and n* values, and increase in tanδ values were encountered at increased water temperatures.
SIGNIFICANCE: The apparent detrimental effect of high temperature on the reduction of properties of adhesives may contribute to the loss of stiffness of the fixed retainer configuration under ordinary clinical conditions with unfavorable effects on tooth position and stability of the orthodontic treatment result.

Abstract

OBJECTIVE: To evaluate the viscoelastic properties of two experimental BPA-free and one BisGMA-based orthodontic resin composite adhesives for bonding fixed retainers.
METHODS: A commercially available BisGMA-based (TXA: Transbond LR) and two bisphenol A-free experimental adhesives (EXA and EXB) were included in the study. The viscoelastic behavior of the adhesives was evaluated under static and dynamic conditions at dry and wet states and at various temperatures (21, 37, 50°C). The parameters determined were shear modulus (G), Young's modulus (E) under static testing and storage modulus (G1), loss tangent (tanδ) and dynamic viscosity (n*) under dynamic testing. Statistical analysis was performed by 2-way ANOVA and Bonferroni post-hoc tests (α=0.05).
RESULTS: For static testing, a significant difference was found within material and storage condition variables and a significant interaction between the two independent variables (p<0.001 for G and E). EXA demonstrated the highest G and E values at 21°C/dry group. Dry specimens showed the highest G and E values, but with no significant difference from 21°C/wet specimens, except EXA in G. Wet storage at higher temperatures (37°C and 50°C) adversely affected all the materials to a degree ranging from 40 to 60% (p<0.001). For dynamic testing, a significant difference was also found in material and testing condition groups, with a significant interaction between the two independent variables (p<0.001 for G1 and n*, p<0.01 for tanδ). Reduction in G1, and n* values, and increase in tanδ values were encountered at increased water temperatures.
SIGNIFICANCE: The apparent detrimental effect of high temperature on the reduction of properties of adhesives may contribute to the loss of stiffness of the fixed retainer configuration under ordinary clinical conditions with unfavorable effects on tooth position and stability of the orthodontic treatment result.

Statistics

Citations

Dimensions.ai Metrics
3 citations in Web of Science®
5 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

140 downloads since deposited on 27 Feb 2018
26 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Orthodontics and Pediatric Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Physical Sciences > General Materials Science
Health Sciences > General Dentistry
Physical Sciences > Mechanics of Materials
Language:English
Date:January 2017
Deposited On:27 Feb 2018 16:11
Last Modified:26 Jan 2022 16:10
Publisher:Elsevier
ISSN:0109-5641
OA Status:Green
Publisher DOI:https://doi.org/10.1016/j.dental.2016.09.041
PubMed ID:27769593
  • Content: Accepted Version
  • Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)