Header

UZH-Logo

Maintenance Infos

Improving FoRe: A New Inlet Design for Filtering Samples through Individual Microarray Spots


de Lange, Victoria; Habegger, Marco; Schmidt, Marco; Vörös, János (2017). Improving FoRe: A New Inlet Design for Filtering Samples through Individual Microarray Spots. ACS Sensors, 2(3):339-345.

Abstract

In this publication we present an improvement to our previously introduced vertical flow microarray, the FoRe array, which capitalizes on the fusion of immunofiltration and densely packed micron test sites. Filtering samples through individual microarray spots allows us to rapidly analyze dilute samples with high-throughput and high signal-to-noise. Unlike other flowthrough microarrays, in the FoRe design samples are injected into micron channels and sequentially exposed to different targets. This arrangement makes it possible to increase the sensitivity of the microarray by simply increasing the sample volume or to rapidly reconcentrate samples after preprocessing steps dilute the analyte. Here we present a new inlet system which allows us to increase the analyzed sample volume without compromising the micron spot size and dense layout. We combined this with a model assay to demonstrate that the device is sensitive to the amount of antigen, and as a result, sample volume directly correlates to sensitivity. We introduced a simple technique for analysis of blood, which previously clogged the nanometer-sized pores, requiring only microliter volumes expected from an infant heel prick. A drop of blood is mixed with buffer to separate the plasma before reconcentrating the sample on the microarray spot. We demonstrated the success of this procedure by spiking TNF-α into blood and achieved a limit of detection of 18 pM. Compared to traditional protein microarrays, the FoRe array is still inexpensive, customizable, and simple to use, and thanks to these improvements has a broad range of applications from small animal studies to environmental monitoring.

Abstract

In this publication we present an improvement to our previously introduced vertical flow microarray, the FoRe array, which capitalizes on the fusion of immunofiltration and densely packed micron test sites. Filtering samples through individual microarray spots allows us to rapidly analyze dilute samples with high-throughput and high signal-to-noise. Unlike other flowthrough microarrays, in the FoRe design samples are injected into micron channels and sequentially exposed to different targets. This arrangement makes it possible to increase the sensitivity of the microarray by simply increasing the sample volume or to rapidly reconcentrate samples after preprocessing steps dilute the analyte. Here we present a new inlet system which allows us to increase the analyzed sample volume without compromising the micron spot size and dense layout. We combined this with a model assay to demonstrate that the device is sensitive to the amount of antigen, and as a result, sample volume directly correlates to sensitivity. We introduced a simple technique for analysis of blood, which previously clogged the nanometer-sized pores, requiring only microliter volumes expected from an infant heel prick. A drop of blood is mixed with buffer to separate the plasma before reconcentrating the sample on the microarray spot. We demonstrated the success of this procedure by spiking TNF-α into blood and achieved a limit of detection of 18 pM. Compared to traditional protein microarrays, the FoRe array is still inexpensive, customizable, and simple to use, and thanks to these improvements has a broad range of applications from small animal studies to environmental monitoring.

Statistics

Citations

Dimensions.ai Metrics
3 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Scopus Subject Areas:Physical Sciences > Bioengineering
Physical Sciences > Instrumentation
Physical Sciences > Process Chemistry and Technology
Physical Sciences > Fluid Flow and Transfer Processes
Language:English
Date:2017
Deposited On:22 Mar 2018 10:20
Last Modified:27 Nov 2020 07:29
Publisher:American Chemical Society (ACS)
ISSN:2379-3694
OA Status:Closed
Publisher DOI:https://doi.org/10.1021/acssensors.6b00271
PubMed ID:28723211

Download

Full text not available from this repository.
View at publisher

Get full-text in a library