The Effect of a New Angiographic Imaging Technology on Radiation Dose in Visceral Embolization Procedures


Baumann, Frederic; Peña, Constantino; Kloeckner, Roman; Katzen, Barry T; Gandhi, Ripal; Benenati, James B (2017). The Effect of a New Angiographic Imaging Technology on Radiation Dose in Visceral Embolization Procedures. Vascular and Endovascular Surgery, 51(4):183-187.

Abstract

PURPOSE To evaluate the impact of a new angiographic imaging technology on radiation dose during visceral embolization procedures involving both fluoroscopy and digital subtraction angiography. MATERIAL AND METHODS A retrospective analysis from a single-center consecutive series of patients was performed comparing 2 angiographic imaging systems. The AlluraClarity (CIQ; Philips Healthcare, Best, the Netherlands) was used in 100 patients (n = 59 male, mean age: 70.6 years) from July 2013 to April 2014 and compared to the former AlluraXper (AX) technology used in 139 patients (n = 71 male, mean age: 70.1 years) from May 2011 to June 2013. Patients were categorized according to body mass index (BMI [kg/m])-group 1: BMI <25, group 2: BMI ≥25 and <30, and group 3: BMI ≥30. Fluoroscopy time, the total dose of iodinated contrast administered, and procedural AirKerma (Ka, r [mGy]) were obtained. RESULTS Mean BMI was 26.4 ± 5.0 kg/m in the CIQ and 26.4 ± 7.1 kg/m in the AX group ( P = .93). Fluoroscopy time and the amount of contrast media were equally distributed. Ka, r was 1342.9 mGy versus 2214.8 mGy ( P < .001, t test) when comparing CIQ to AX. Comparing CIQ to AX, BMI subgroup analysis revealed a mean Ka, r of 970.1 to 1586.1 mGy ( P = .003, t test), 1484.7 to 2170.1 mGy ( P = .02, t test), and 1848.8 to 3348.9 mGy ( P = .001, t test) in BMI groups 1, 2, and 3, respectively. CONCLUSION The CIQ technology significantly reduced mean radiation dose by 39.4% for visceral embolization procedures when compared to fluoroscopy time and contrast media dose. This dose relationship was consistent across all BMI groups.

Abstract

PURPOSE To evaluate the impact of a new angiographic imaging technology on radiation dose during visceral embolization procedures involving both fluoroscopy and digital subtraction angiography. MATERIAL AND METHODS A retrospective analysis from a single-center consecutive series of patients was performed comparing 2 angiographic imaging systems. The AlluraClarity (CIQ; Philips Healthcare, Best, the Netherlands) was used in 100 patients (n = 59 male, mean age: 70.6 years) from July 2013 to April 2014 and compared to the former AlluraXper (AX) technology used in 139 patients (n = 71 male, mean age: 70.1 years) from May 2011 to June 2013. Patients were categorized according to body mass index (BMI [kg/m])-group 1: BMI <25, group 2: BMI ≥25 and <30, and group 3: BMI ≥30. Fluoroscopy time, the total dose of iodinated contrast administered, and procedural AirKerma (Ka, r [mGy]) were obtained. RESULTS Mean BMI was 26.4 ± 5.0 kg/m in the CIQ and 26.4 ± 7.1 kg/m in the AX group ( P = .93). Fluoroscopy time and the amount of contrast media were equally distributed. Ka, r was 1342.9 mGy versus 2214.8 mGy ( P < .001, t test) when comparing CIQ to AX. Comparing CIQ to AX, BMI subgroup analysis revealed a mean Ka, r of 970.1 to 1586.1 mGy ( P = .003, t test), 1484.7 to 2170.1 mGy ( P = .02, t test), and 1848.8 to 3348.9 mGy ( P = .001, t test) in BMI groups 1, 2, and 3, respectively. CONCLUSION The CIQ technology significantly reduced mean radiation dose by 39.4% for visceral embolization procedures when compared to fluoroscopy time and contrast media dose. This dose relationship was consistent across all BMI groups.

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

62 downloads since deposited on 08 May 2018
21 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Angiology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:May 2017
Deposited On:08 May 2018 13:09
Last Modified:26 Jan 2022 16:51
Publisher:Sage Publications Ltd.
ISSN:1538-5744
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1177/1538574417698903
PubMed ID:28424042

Download

Green Open Access