Evaluation of a modified Cheatham-Platinum stent for the treatment of aortic coarctation by finite element modelling


Burkhardt, Barbara E U; Byrne, Nicholas; Velasco Forte, Marí Nieves; Iannaccone, Francesco; De Beule, Matthieu; Morgan, Gareth J; Hussain, Tarique (2018). Evaluation of a modified Cheatham-Platinum stent for the treatment of aortic coarctation by finite element modelling. JRSM Cardiovascular Disease, 7:2048004018773958.

Abstract

Objectives: Stent implantation for the treatment of aortic coarctation has become a standard approach for the management of older children and adults. Criteria for optimal stent design and construction remain undefined. This study used computational modelling to compare the performance of two generations of the Cheatham-Platinum stent (NuMED, Hopkinton, NY, USA) deployed in aortic coarctation using finite element analysis.
Design: Three-dimensional models of both stents, reverse engineered from microCT scans, were implanted in the aortic model of one representative patient. They were virtually expanded in the vessel with a 16 mm balloon and a pressure of 2 atm.
Results: The conventional stent foreshortened to 96.5% of its initial length, whereas the new stent to 99.2% of its initial length. Diameters in 15 slices across the conventional stent were 11.6-15 mm (median 14.2 mm) and slightly higher across the new stent: 10.7-15.3 mm (median 14.5 mm) (p= 0.021). Apposition to the vessel wall was similar: conventional stent 31.1% and new stent 28.6% of total stent area.
Conclusions: The new design Cheatham-Platinum stent showed similar deployment results compared to the conventional design. The new stent design showed slightly higher expansion, using the same delivery balloon. Patient-specific computational models can be used for virtual implantation of new aortic stents and promise to inform subsequent in vivo trials.

Abstract

Objectives: Stent implantation for the treatment of aortic coarctation has become a standard approach for the management of older children and adults. Criteria for optimal stent design and construction remain undefined. This study used computational modelling to compare the performance of two generations of the Cheatham-Platinum stent (NuMED, Hopkinton, NY, USA) deployed in aortic coarctation using finite element analysis.
Design: Three-dimensional models of both stents, reverse engineered from microCT scans, were implanted in the aortic model of one representative patient. They were virtually expanded in the vessel with a 16 mm balloon and a pressure of 2 atm.
Results: The conventional stent foreshortened to 96.5% of its initial length, whereas the new stent to 99.2% of its initial length. Diameters in 15 slices across the conventional stent were 11.6-15 mm (median 14.2 mm) and slightly higher across the new stent: 10.7-15.3 mm (median 14.5 mm) (p= 0.021). Apposition to the vessel wall was similar: conventional stent 31.1% and new stent 28.6% of total stent area.
Conclusions: The new design Cheatham-Platinum stent showed similar deployment results compared to the conventional design. The new stent design showed slightly higher expansion, using the same delivery balloon. Patient-specific computational models can be used for virtual implantation of new aortic stents and promise to inform subsequent in vivo trials.

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Downloads

56 downloads since deposited on 20 Jun 2018
51 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:27 April 2018
Deposited On:20 Jun 2018 13:50
Last Modified:22 Oct 2019 07:33
Publisher:Sage Publications Ltd.
ISSN:20480040
OA Status:Green
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1177/2048004018773958
Related URLs:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5944143/
PubMed ID:29760913
Other Identification Number:PMCID: PMC5944143

Download

Green Open Access

Download PDF  'Evaluation of a modified Cheatham-Platinum stent for the treatment of aortic coarctation by finite element modelling'.
Preview
Content: Published Version
Language: English
Filetype: PDF
Size: 504kB
View at publisher
Licence: Creative Commons: Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)