Whole-heart 4D flow cardiac magnetic resonance in healthy dogs


Pfammatter, Nadia; Campagna, Ivo; Baron Toaldo, M; Bruellmann, E; Richter, Henning; Kircher, Patrick R; Dennler, Matthias (2018). Whole-heart 4D flow cardiac magnetic resonance in healthy dogs. Schweizer Archiv für Tierheilkunde, 160(5):295-303.

Abstract

In cardiac magnetic resonance imaging (CMR), accurate flow measurements rely on perpendicular plane-alignment with flow direction. For 2D phase contrast (PC) cardiac magnetic resonance measurements, planes have to be defined during the examination of the heart, which is time consuming and error-prone. Collection of flow information of the entire volume of the heart by a 4D flow CMR postpones plane alignment to post-processing. Sampling of such a large amount of data requires acceleration of data acquisition with techniques such as SENSitivity Encoding (k-t SENSE) or Broad-use Linear Acquisition Speed-up Technique (k-t BLAST). Objectives of the study were to compare 4D flow CMR, accelerated with two different acceleration methods with the established 2D PC CMR based on assessment of stroke volume at all four cardiac valves. The values of stroke volume acquired with the 4D flow CMR SENSE did not differ significantly when compared to the 2D PC CMR SENSE at the left side of the heart (aortic and mitral valve). Significant differences between the techniques were seen at the pulmonic and tricuspid valves. Acceleration with k-t BLAST revealed significantly lower values of stroke volume at all cardiac valves, except at the mitral valve.

Abstract

In cardiac magnetic resonance imaging (CMR), accurate flow measurements rely on perpendicular plane-alignment with flow direction. For 2D phase contrast (PC) cardiac magnetic resonance measurements, planes have to be defined during the examination of the heart, which is time consuming and error-prone. Collection of flow information of the entire volume of the heart by a 4D flow CMR postpones plane alignment to post-processing. Sampling of such a large amount of data requires acceleration of data acquisition with techniques such as SENSitivity Encoding (k-t SENSE) or Broad-use Linear Acquisition Speed-up Technique (k-t BLAST). Objectives of the study were to compare 4D flow CMR, accelerated with two different acceleration methods with the established 2D PC CMR based on assessment of stroke volume at all four cardiac valves. The values of stroke volume acquired with the 4D flow CMR SENSE did not differ significantly when compared to the 2D PC CMR SENSE at the left side of the heart (aortic and mitral valve). Significant differences between the techniques were seen at the pulmonic and tricuspid valves. Acceleration with k-t BLAST revealed significantly lower values of stroke volume at all cardiac valves, except at the mitral valve.

Statistics

Citations

Altmetrics

Downloads

48 downloads since deposited on 20 Jul 2018
45 downloads since 12 months
Detailed statistics

Additional indexing

Other titles:4D Flussmessungen im Herzen mit kardialer Magnetresonanztomographie bei gesunden Hunden
Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals
05 Vetsuisse Faculty > Veterinary Clinic > Department of Clinical Diagnostics and Services
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Uncontrolled Keywords:cardiac flow quantification, canine, 4D magnetic resonance imaging, k-t SENSE, k-t-BLAST, phase contrast angiography
Language:English
Date:2018
Deposited On:20 Jul 2018 10:20
Last Modified:24 Sep 2019 23:32
Publisher:Gesellschaft Schweizer Tierärztinnen und Tierärzte
ISSN:0036-7281
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.17236/sat00159
PubMed ID:29717983

Download

Download PDF  'Whole-heart 4D flow cardiac magnetic resonance in healthy dogs'.
Preview
Content: Published Version
Language: English
Filetype: PDF
Size: 596kB
View at publisher