Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial

Schwitter, Juerg; Wacker, Christian M; van Rossum, Albert C; Lombardi, Massimo; Al-Saadi, Nidal; Ahlstrom, Hakan; Dill, Thorsten; Larsson, Henrik B W; Flamm, Scott D; Marquardt, Moritz; Johansson, Lars (2008). MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial. European Heart Journal, 29(4):480-489.

Abstract

Aims To determine in a multicentre, multivendor trial the diagnostic performance for perfusion-cardiac magnetic resonance (perfusion-CMR) in comparison with coronary X-ray angiography (CXA) and single-photon emission computed tomography (SPECT). Methods and results Of 241 eligible patients from 18 centres, 234 were randomly dosed with 0.01, 0.025, 0.05, 0.075, or 0.1 mmol/kg Gd-DTPA-BMA (Omniscan™, GE-Healthcare) per stress (0.42 mg/kg adenosine) and rest perfusion study. Coronary artery disease (CAD) was defined as diameter stenosis ≥50% on quantitative CXA. Five CMR and eight SPECT studies (of 225 complete studies) were excluded from analyses due to inadequate quality (three blinded readers scored per modality). The comparison of CMR vs. SPECT was based on receiver operating characteristic (ROC) analysis. Perfusion-CMR at the optimal CM dose (0.1 mmol/kg) had similar performance as SPECT, if only the SPECT studies of the 42 patients with this dose were considered [area under ROC curve (AUC): 0.86 ± 0.06 vs. 0.75 ± 0.09 for SPECT, P = 0.12]; however, diagnostic performance of perfusion-CMR was better vs. the entire SPECT population (AUC: 0.67 ± 0.05, n = 212, P = 0.013). Conclusions In this multicentre, multivendor trial, ROC analyses suggest perfusion-CMR as a valuable alternative to SPECT for CAD detection showing equal performance in the head-to-head comparison. Comparing perfusion-CMR with the entire SPECT population suggests CMR superiority over SPECT, which warrants further evaluation in larger trials

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:National licences > 142-005
Dewey Decimal Classification:570 Life sciences; biology
610 Medicine & health
Scopus Subject Areas:Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:1 February 2008
Deposited On:17 Oct 2018 16:11
Last Modified:25 Aug 2024 03:33
Publisher:Oxford University Press
ISSN:0195-668X
OA Status:Hybrid
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1093/eurheartj/ehm617
PubMed ID:18208849
Download PDF  'MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial'.
Preview
  • Content: Published Version
  • Language: English
  • Description: Nationallizenz 142-005

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
463 citations in Web of Science®
543 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

248 downloads since deposited on 17 Oct 2018
53 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations