Left ventricular volume determination in dogs: a comparison between conductance technique and angiocardiography


Tjon-A-Meeuw, L; Hess, O M; Nonogi, H; Monrad, E S; Leskosek, B; Krayenbuehl, H P (1988). Left ventricular volume determination in dogs: a comparison between conductance technique and angiocardiography. European Heart Journal, 9(9):1018-1026.

Abstract

Left ventricular (LV) volume was determined simultaneously by monoplane cineangiocardiography and conductivity using a multielectrode conductance catheter at rest and during pressure loading in seven mongrel dogs (mean body weight 22 kg). LV volumes were calculated frame-by-frame (75 frames s−1) by angiocardiography and matched with instantaneous volumes obtained by conductivity. There was an excellent correlation between the two techniques at rest (correlation coefficient, r = 0.96) and during pressure loading (r = 0.92) when the data of each dog were pooled. The standard error of estimate of the mean angiographic volume was 4%. The slope of the regression analysis showed a small but significant (P <0.01) decrease from 0.365 at rest to 0.289 during pressure loading, whereas the intercept remained unchanged (24 versus 26 ml). Since no calibration for parallel conductivity of the surrounding tissue was performed, LV end-systolic volume was significantly over- and LV ejection fraction significantly underestimated whereas LV end-diastolic volume was estimated correctly by the conductance technique. It is concluded that LV end-diastolic volume can be determined accurately by the conductance technique in dogs. However, LV end-systolic volume is significantly over- and ejection fraction significantly under-estimated. Since there is a good correlation between angiocardiography and conductivity, exact determination Of LV volumes and ejection fraction is feasible using a correction factor. The change is slope of the regression equation between angiocardiography and conductivity suggests a change in conductivity of the surrounding tissue during pressure loading which limits the application of the conductance catheter to stable haemodynamic situations or calls for repeated calibrations by an independent technique during acute interventions

Abstract

Left ventricular (LV) volume was determined simultaneously by monoplane cineangiocardiography and conductivity using a multielectrode conductance catheter at rest and during pressure loading in seven mongrel dogs (mean body weight 22 kg). LV volumes were calculated frame-by-frame (75 frames s−1) by angiocardiography and matched with instantaneous volumes obtained by conductivity. There was an excellent correlation between the two techniques at rest (correlation coefficient, r = 0.96) and during pressure loading (r = 0.92) when the data of each dog were pooled. The standard error of estimate of the mean angiographic volume was 4%. The slope of the regression analysis showed a small but significant (P <0.01) decrease from 0.365 at rest to 0.289 during pressure loading, whereas the intercept remained unchanged (24 versus 26 ml). Since no calibration for parallel conductivity of the surrounding tissue was performed, LV end-systolic volume was significantly over- and LV ejection fraction significantly underestimated whereas LV end-diastolic volume was estimated correctly by the conductance technique. It is concluded that LV end-diastolic volume can be determined accurately by the conductance technique in dogs. However, LV end-systolic volume is significantly over- and ejection fraction significantly under-estimated. Since there is a good correlation between angiocardiography and conductivity, exact determination Of LV volumes and ejection fraction is feasible using a correction factor. The change is slope of the regression equation between angiocardiography and conductivity suggests a change in conductivity of the surrounding tissue during pressure loading which limits the application of the conductance catheter to stable haemodynamic situations or calls for repeated calibrations by an independent technique during acute interventions

Statistics

Citations

Dimensions.ai Metrics
13 citations in Web of Science®
13 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

10 downloads since deposited on 17 Oct 2018
10 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:National licences > 142-005
Dewey Decimal Classification:570 Life sciences; biology
610 Medicine & health
Language:English
Date:1 September 1988
Deposited On:17 Oct 2018 14:57
Last Modified:24 Nov 2018 02:57
Publisher:Oxford University Press
ISSN:0195-668X
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1093/oxfordjournals.eurheartj.a062593
Related URLs:https://www.swissbib.ch/Search/Results?lookfor=nationallicenceoxford101093oxfordjournalseurheartja062593 (Library Catalogue)

Download

Download PDF  'Left ventricular volume determination in dogs: a comparison between conductance technique and angiocardiography'.
Preview
Content: Published Version
Language: English
Filetype: PDF (Nationallizenz 142-005)
Size: 2MB
View at publisher