Compartmental Bone Morphometry in the Mouse Femur: Reproducibility and Resolution Dependence of Microtomographic Measurements


Kohler, T; Beyeler, M; Webster, D; Müller, R (2005). Compartmental Bone Morphometry in the Mouse Femur: Reproducibility and Resolution Dependence of Microtomographic Measurements. Calcified tissue international, 77(5):281-290.

Abstract

Microcomputed tomography (μCT) is widely used for nondestructive bone phenotyping in small animals, especially in the mouse. Here, we investigated the reproducibility and resolution dependence of μCT analysis of microstructural parameters in three different compartments in the mouse femur. Reproducibility was assessed with respect to precision error (PE%CV) and intraclass correlation coefficient (ICC). We examined 14 left femurs isolated postmortem from two strains of mice (seven per group). Measurements and analyses were repeated five times on different days. In a second step, analysis was repeated again five times for a single measurement. Resolution dependence was assessed by high-resolution measurements (10μm) in one strain and subsequent image degrading. Reproducibility was better in full bone compartment and in cortical bone compartment in the diaphysis (PE%CV = 0.06-2.16%) than in trabecular compartment in the distal metaphysis (PE%CV = 0.59-5.24%). Nevertheless, ICC (0.92-1.00) showed a very high reliability of the assessed parameters in all regions, indicating very small variances within repeated measurements compared to the population variances. Morphometric indices computed from lower- and higher-resolution images displayed in general only weak dependence and were highly correlated with each other (R2 = 0.91-0.99). The results show that parameters in the full and cortical compartments were very reproducible, whereas precision in the trabecular compartment was somewhat lower. Nevertheless, all compartmental analysis methods were very robust, as shown by the high ICC values, demonstrating high suitability for application in inbred strains, where highest precision is needed due to small population variances

Abstract

Microcomputed tomography (μCT) is widely used for nondestructive bone phenotyping in small animals, especially in the mouse. Here, we investigated the reproducibility and resolution dependence of μCT analysis of microstructural parameters in three different compartments in the mouse femur. Reproducibility was assessed with respect to precision error (PE%CV) and intraclass correlation coefficient (ICC). We examined 14 left femurs isolated postmortem from two strains of mice (seven per group). Measurements and analyses were repeated five times on different days. In a second step, analysis was repeated again five times for a single measurement. Resolution dependence was assessed by high-resolution measurements (10μm) in one strain and subsequent image degrading. Reproducibility was better in full bone compartment and in cortical bone compartment in the diaphysis (PE%CV = 0.06-2.16%) than in trabecular compartment in the distal metaphysis (PE%CV = 0.59-5.24%). Nevertheless, ICC (0.92-1.00) showed a very high reliability of the assessed parameters in all regions, indicating very small variances within repeated measurements compared to the population variances. Morphometric indices computed from lower- and higher-resolution images displayed in general only weak dependence and were highly correlated with each other (R2 = 0.91-0.99). The results show that parameters in the full and cortical compartments were very reproducible, whereas precision in the trabecular compartment was somewhat lower. Nevertheless, all compartmental analysis methods were very robust, as shown by the high ICC values, demonstrating high suitability for application in inbred strains, where highest precision is needed due to small population variances

Statistics

Citations

Dimensions.ai Metrics
60 citations in Web of Science®
63 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

37 downloads since deposited on 23 Oct 2018
23 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:National licences > 142-005
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Endocrinology, Diabetes and Metabolism
Health Sciences > Orthopedics and Sports Medicine
Life Sciences > Endocrinology
Language:English
Date:1 November 2005
Deposited On:23 Oct 2018 15:17
Last Modified:15 Apr 2021 14:52
Publisher:Springer
ISSN:0171-967X
OA Status:Green
Publisher DOI:https://doi.org/10.1007/s00223-005-0039-2

Download

Green Open Access

Download PDF  'Compartmental Bone Morphometry in the Mouse Femur: Reproducibility and Resolution Dependence of Microtomographic Measurements'.
Preview
Content: Published Version
Language: English
Filetype: PDF (Nationallizenz 142-005)
Size: 232kB
View at publisher