Unterer, S; Gerber, Bernhard; Glaus, Toni M; Hässig, Michael; Reusch, Claudia E (2005). Evaluation of an electrolyte analyser for measurement of concentrations of ionized calcium and magnesium in cats. Veterinary Research Communications, 29(8):647-659.

Abstract

The goal of this study was to evaluate the Nova CRT 8 electrolyte analyser for determination of concentrations of ionized calcium (Cai) and magnesium (Mgi) in cats, todetermine the effects of sample handling and storage and to establish reference ranges. The precision and analytical accuracy of the Nova CRT 8 analyser were good. The concentrations of Cai and Mgi were significantly lower in aerobically handled serum samples than in those handled anaerobically. The concentrations of Cai and Mgi differed significantly among whole blood, plasma and serum. In anaerobically handled serum, the concentration of Cai was stable for 8 h at 22°C, for 5 days at 4°C and for 1 week at −20°C. The concentration of Mgi was stable for 4 h at 22°C but for less than 24 h at 4°C and for less than 1 week at −20°C. In serum from 36 cats, the reference ranges were 1.20-1.35 mmol/L for Cai and 0.47-0.59 mmol/L for Mgi. The Nova CRT 8 electrolyte analyser is suitable for determination of Cai and Mgi concentrations in cats. Anaerobically handled serum samples are recommended and, stored at room temperature, they yield accurate results when analysed within 4 h

Abstract

The goal of this study was to evaluate the Nova CRT 8 electrolyte analyser for determination of concentrations of ionized calcium (Cai) and magnesium (Mgi) in cats, todetermine the effects of sample handling and storage and to establish reference ranges. The precision and analytical accuracy of the Nova CRT 8 analyser were good. The concentrations of Cai and Mgi were significantly lower in aerobically handled serum samples than in those handled anaerobically. The concentrations of Cai and Mgi differed significantly among whole blood, plasma and serum. In anaerobically handled serum, the concentration of Cai was stable for 8 h at 22°C, for 5 days at 4°C and for 1 week at −20°C. The concentration of Mgi was stable for 4 h at 22°C but for less than 24 h at 4°C and for less than 1 week at −20°C. In serum from 36 cats, the reference ranges were 1.20-1.35 mmol/L for Cai and 0.47-0.59 mmol/L for Mgi. The Nova CRT 8 electrolyte analyser is suitable for determination of Cai and Mgi concentrations in cats. Anaerobically handled serum samples are recommended and, stored at room temperature, they yield accurate results when analysed within 4 h

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
6 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

23 downloads since deposited on 19 Dec 2018
23 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals
National licences > 142-005
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Language:English
Date:1 November 2005
Deposited On:19 Dec 2018 15:16
Last Modified:24 Sep 2019 23:46
Publisher:Springer
ISSN:0165-7380
OA Status:Green
Publisher DOI:https://doi.org/10.1007/s11259-005-3301-1
Related URLs:https://www.swissbib.ch/Search/Results?lookfor=nationallicencespringer101007s1125900533011 (Library Catalogue)
PubMed ID:16369879

Download

Download PDF  'Evaluation of an electrolyte analyser for measurement of concentrations of ionized calcium and magnesium in cats'.
Preview
Content: Published Version
Language: English
Filetype: PDF (Nationallizenz 142-005)
Size: 204kB
View at publisher