Precision of digital implant models compared to conventional implant models for posterior single implant crowns: A within-subject comparison


Mühlemann, Sven; Greter, Elena A; Park, Ji-Man; Hämmerle, Christoph H F; Thoma, Daniel S (2018). Precision of digital implant models compared to conventional implant models for posterior single implant crowns: A within-subject comparison. Clinical Oral Implants Research, 29(9):931-936.

Abstract

OBJECTIVE To calculate the precision of the implant analog position in digital models generated from different computer-assisted design and computer-assisted manufacturing (CAD-CAM) systems compared to gypsum models acquired from conventional implant impressions. MATERIALS AND METHODS In five patients in need of a single implant crown, a within-subject comparison was performed applying four different manufacturing processes for the implant model. Each implant was scanned with three different intraoral scanners: iTero Cadent (ITE), Lava True Definition (LTD), and Trios 3Shape (TRI). All digital implant models were fabricated using the corresponding certified CAD-CAM workflow. In addition, a conventional impression was taken (CON) and a gypsum model fabricated. Three consecutive impressions were acquired with each impression system. Following fabrication, all implant models were scanned. The datasets were aligned by a repeated best-fit algorithm and the precision for the implant analog and the adjacent teeth was measured. The precision served as a measure for reproducibility. RESULTS Mean precision values of the implant analog in the digital models were 57.2 ± 32.6 µm (ITE), 88.6 ± 46.0 µm (TRI), and 176.7 ± 120.4 µm (LTD). Group CON (32.7 ± 11.6 µm) demonstrated a statistically significantly lower mean precision value for the implant position in the implant model as compared to all other groups representing a high reproducibility. The mean precision values for the reference ranged between 31.4 ± 3.5 µm (TRI) and 39.5 ± 16.5 µm (ITE). No statistical significant difference was calculated between the four treatment groups. CONCLUSIONS The conventional implant model represented the greatest reproducibility of the implant position. Digital implant models demonstrated less precision compared to the conventional workflow.

Abstract

OBJECTIVE To calculate the precision of the implant analog position in digital models generated from different computer-assisted design and computer-assisted manufacturing (CAD-CAM) systems compared to gypsum models acquired from conventional implant impressions. MATERIALS AND METHODS In five patients in need of a single implant crown, a within-subject comparison was performed applying four different manufacturing processes for the implant model. Each implant was scanned with three different intraoral scanners: iTero Cadent (ITE), Lava True Definition (LTD), and Trios 3Shape (TRI). All digital implant models were fabricated using the corresponding certified CAD-CAM workflow. In addition, a conventional impression was taken (CON) and a gypsum model fabricated. Three consecutive impressions were acquired with each impression system. Following fabrication, all implant models were scanned. The datasets were aligned by a repeated best-fit algorithm and the precision for the implant analog and the adjacent teeth was measured. The precision served as a measure for reproducibility. RESULTS Mean precision values of the implant analog in the digital models were 57.2 ± 32.6 µm (ITE), 88.6 ± 46.0 µm (TRI), and 176.7 ± 120.4 µm (LTD). Group CON (32.7 ± 11.6 µm) demonstrated a statistically significantly lower mean precision value for the implant position in the implant model as compared to all other groups representing a high reproducibility. The mean precision values for the reference ranged between 31.4 ± 3.5 µm (TRI) and 39.5 ± 16.5 µm (ITE). No statistical significant difference was calculated between the four treatment groups. CONCLUSIONS The conventional implant model represented the greatest reproducibility of the implant position. Digital implant models demonstrated less precision compared to the conventional workflow.

Statistics

Citations

Altmetrics

Downloads

3 downloads since deposited on 04 Oct 2018
3 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:1 September 2018
Deposited On:04 Oct 2018 09:39
Last Modified:04 Oct 2018 09:48
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0905-7161
Additional Information:This is the peer reviewed version of the following article: Mühlemann, Sven; Greter, Elena A; Park, Ji-Man; Hämmerle, Christoph H F; Thoma, Daniel S (2018). Precision of digital implant models compared to conventional implant models for posterior single implant crowns: A within-subject comparison. Clinical Oral Implants Research, 29(9):931-936, which has been published in final form at https://doi.org/10.1111/clr.13349. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving (http://olabout.wiley.com/WileyCDA/Section/id-820227.html#terms).
OA Status:Closed
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1111/clr.13349
PubMed ID:30168207

Download