Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Early Recoil After Balloon Angioplasty of Erection-Related Arteries in Patients With Arteriogenic Erectile Dysfunction

Diehm, Nicolas; Do, Dai-Do; Keo, Hak-Hong; Boerlin, Jana; Regli, Christian; Schumacher, Martin; Jungmann, Pia M; Raeber, Lorenz; Baumann, Frederic (2018). Early Recoil After Balloon Angioplasty of Erection-Related Arteries in Patients With Arteriogenic Erectile Dysfunction. Journal of Endovascular Therapy, 25(6):710-715.

Abstract

PURPOSE To evaluate the incidence of elastic recoil in patients presenting with erectile dysfunction (ED) undergoing endovascular revascularization of the pudendal or penile arteries. METHODS A consecutive series of 21 ED patients (mean age 58.3±9.3 years) undergoing minimally invasive revascularization of 31 arteries was analyzed. ED lesions included the pudendal arteries (n=27) and the penile artery (n=4). Mean lesion length was 20.6±13.9 mm. Minimal lumen diameter (MLD) measurements were assessed at baseline, immediately after balloon angioplasty, and 10 minutes thereafter. Early recoil was defined as an MLD reduction >10%. Elastic recoil with >10% lumen compromise was treated with drug-coated balloons, while severe elastic recoil (>30%) required drug-eluting stents (DES). The International Index of Erectile Function (IIEF-15) score was obtained prior to and 3 months after the procedure to obtain information on functional outcomes subsequent to angioplasty. RESULTS Mean MLD at baseline was 0.9±0.6 mm, which improved to 2.0±0.9 mm immediately after balloon dilation. At 10 minutes after dilation, the MLD was 1.7±1.0 mm. Elastic recoil was observed in all 31 lesions and resulted in a mean lumen compromise of 21.2%. Severe (>30%) recoil was observed in 14 arteries, which underwent DES therapy. The IIEF-15 score improved from 31.3±11.2 at baseline to 49.8±16.8 (p<0.001) at the 3-month follow-up. CONCLUSION Endovascular revascularization constitutes a safe and feasible treatment modality to restore erectile function in patients with arteriogenic ED and ineffective conservative management. Early elastic recoil is very frequent subsequent to balloon dilation of small-caliber erection-related arteries. Thus, mechanical scaffolding with DES is required in a high subset of ED patients to provide favorable early angiographic and clinical results.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Angiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Neuroradiology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Radiology, Nuclear Medicine and Imaging
Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:1 December 2018
Deposited On:31 Oct 2018 15:05
Last Modified:24 Feb 2025 04:32
Publisher:Sage Publications
ISSN:1526-6028
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1177/1526602818807704
PubMed ID:30343612
Download PDF  'Early Recoil After Balloon Angioplasty of Erection-Related Arteries in Patients With Arteriogenic Erectile Dysfunction'.
Preview
  • Content: Published Version

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
9 citations in Web of Science®
9 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

524 downloads since deposited on 31 Oct 2018
64 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications