Early Recoil After Balloon Angioplasty of Erection-Related Arteries in Patients With Arteriogenic Erectile Dysfunction


Diehm, Nicolas; Do, Dai-Do; Keo, Hak-Hong; Boerlin, Jana; Regli, Christian; Schumacher, Martin; Jungmann, Pia M; Raeber, Lorenz; Baumann, Frederic (2018). Early Recoil After Balloon Angioplasty of Erection-Related Arteries in Patients With Arteriogenic Erectile Dysfunction. Journal of Endovascular Therapy, 25(6):710-715.

Abstract

PURPOSE To evaluate the incidence of elastic recoil in patients presenting with erectile dysfunction (ED) undergoing endovascular revascularization of the pudendal or penile arteries. METHODS A consecutive series of 21 ED patients (mean age 58.3±9.3 years) undergoing minimally invasive revascularization of 31 arteries was analyzed. ED lesions included the pudendal arteries (n=27) and the penile artery (n=4). Mean lesion length was 20.6±13.9 mm. Minimal lumen diameter (MLD) measurements were assessed at baseline, immediately after balloon angioplasty, and 10 minutes thereafter. Early recoil was defined as an MLD reduction >10%. Elastic recoil with >10% lumen compromise was treated with drug-coated balloons, while severe elastic recoil (>30%) required drug-eluting stents (DES). The International Index of Erectile Function (IIEF-15) score was obtained prior to and 3 months after the procedure to obtain information on functional outcomes subsequent to angioplasty. RESULTS Mean MLD at baseline was 0.9±0.6 mm, which improved to 2.0±0.9 mm immediately after balloon dilation. At 10 minutes after dilation, the MLD was 1.7±1.0 mm. Elastic recoil was observed in all 31 lesions and resulted in a mean lumen compromise of 21.2%. Severe (>30%) recoil was observed in 14 arteries, which underwent DES therapy. The IIEF-15 score improved from 31.3±11.2 at baseline to 49.8±16.8 (p<0.001) at the 3-month follow-up. CONCLUSION Endovascular revascularization constitutes a safe and feasible treatment modality to restore erectile function in patients with arteriogenic ED and ineffective conservative management. Early elastic recoil is very frequent subsequent to balloon dilation of small-caliber erection-related arteries. Thus, mechanical scaffolding with DES is required in a high subset of ED patients to provide favorable early angiographic and clinical results.

Abstract

PURPOSE To evaluate the incidence of elastic recoil in patients presenting with erectile dysfunction (ED) undergoing endovascular revascularization of the pudendal or penile arteries. METHODS A consecutive series of 21 ED patients (mean age 58.3±9.3 years) undergoing minimally invasive revascularization of 31 arteries was analyzed. ED lesions included the pudendal arteries (n=27) and the penile artery (n=4). Mean lesion length was 20.6±13.9 mm. Minimal lumen diameter (MLD) measurements were assessed at baseline, immediately after balloon angioplasty, and 10 minutes thereafter. Early recoil was defined as an MLD reduction >10%. Elastic recoil with >10% lumen compromise was treated with drug-coated balloons, while severe elastic recoil (>30%) required drug-eluting stents (DES). The International Index of Erectile Function (IIEF-15) score was obtained prior to and 3 months after the procedure to obtain information on functional outcomes subsequent to angioplasty. RESULTS Mean MLD at baseline was 0.9±0.6 mm, which improved to 2.0±0.9 mm immediately after balloon dilation. At 10 minutes after dilation, the MLD was 1.7±1.0 mm. Elastic recoil was observed in all 31 lesions and resulted in a mean lumen compromise of 21.2%. Severe (>30%) recoil was observed in 14 arteries, which underwent DES therapy. The IIEF-15 score improved from 31.3±11.2 at baseline to 49.8±16.8 (p<0.001) at the 3-month follow-up. CONCLUSION Endovascular revascularization constitutes a safe and feasible treatment modality to restore erectile function in patients with arteriogenic ED and ineffective conservative management. Early elastic recoil is very frequent subsequent to balloon dilation of small-caliber erection-related arteries. Thus, mechanical scaffolding with DES is required in a high subset of ED patients to provide favorable early angiographic and clinical results.

Statistics

Citations

Dimensions.ai Metrics
2 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

59 downloads since deposited on 31 Oct 2018
59 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Angiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Neuroradiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:1 December 2018
Deposited On:31 Oct 2018 15:05
Last Modified:10 Nov 2018 02:05
Publisher:International Society of Endovascular Specialists
ISSN:1526-6028
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1177/1526602818807704
PubMed ID:30343612

Download

Download PDF  'Early Recoil After Balloon Angioplasty of Erection-Related Arteries in Patients With Arteriogenic Erectile Dysfunction'.
Preview
Content: Published Version
Filetype: PDF
Size: 164kB
View at publisher