Header

UZH-Logo

Maintenance Infos

Characterisation of Silicon Photomultipliers for liquid xenon detectors


Baudis, L; Galloway, M; Kish, A; Marentini, C; Wulf, J (2018). Characterisation of Silicon Photomultipliers for liquid xenon detectors. Journal of Instrumentation, 13(10):P10022.

Abstract

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the vacuum ultraviolet scintillation light from LXe at 178 nm with high resolution and detection efficiency and low noise rates. Further requirements for dark matter and double beta decay searches are ultra-low radioactivity levels of all the components including the substrates and cold electronics. Here we describe our characterisation of Hamamatsu 6×6 mm2 SiPMs in the temperature range 110–300 K in nitrogen gas, as well as long-term measurements in cold nitrogen gas at 172 K and liquid xenon at 185 K. After we introduce the experimental setups, the data acquisition schemes and analysis methods, we show the single-photon response, the gain versus bias voltage, as well as the dark and correlated noise rates. We demonstrate the long-term stability at cryogenic temperatures, and conclude that SiPM arrays are promising candidates for photosensor arrays in liquid xenon detectors. Furthermore, we study the radioactivity of the raw SiPM materials with gamma spectrometry and inductively coupled plasma mass spectrometry and conclude that SiPMs are suitable for use in low-background experiments.

Abstract

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the vacuum ultraviolet scintillation light from LXe at 178 nm with high resolution and detection efficiency and low noise rates. Further requirements for dark matter and double beta decay searches are ultra-low radioactivity levels of all the components including the substrates and cold electronics. Here we describe our characterisation of Hamamatsu 6×6 mm2 SiPMs in the temperature range 110–300 K in nitrogen gas, as well as long-term measurements in cold nitrogen gas at 172 K and liquid xenon at 185 K. After we introduce the experimental setups, the data acquisition schemes and analysis methods, we show the single-photon response, the gain versus bias voltage, as well as the dark and correlated noise rates. We demonstrate the long-term stability at cryogenic temperatures, and conclude that SiPM arrays are promising candidates for photosensor arrays in liquid xenon detectors. Furthermore, we study the radioactivity of the raw SiPM materials with gamma spectrometry and inductively coupled plasma mass spectrometry and conclude that SiPMs are suitable for use in low-background experiments.

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

20 downloads since deposited on 30 Nov 2018
19 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:07 Faculty of Science > Physics Institute
Dewey Decimal Classification:530 Physics
Scopus Subject Areas:Physical Sciences > Instrumentation
Physical Sciences > Mathematical Physics
Uncontrolled Keywords:Instrumentation, Mathematical Physics
Language:English
Date:16 October 2018
Deposited On:30 Nov 2018 14:39
Last Modified:15 Apr 2020 21:53
Publisher:IOP Publishing
ISSN:1748-0221
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1088/1748-0221/13/10/p10022

Download

Green Open Access

Download PDF  'Characterisation of Silicon Photomultipliers for liquid xenon detectors'.
Preview
Content: Accepted Version
Filetype: PDF
Size: 2MB
View at publisher