Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine

Revilla-León, Marta; Gonzalez-Martín, Óscar; Pérez López, Javier; Sánchez-Rubio, José Luis; Özcan, Mutlu (2018). Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine. Journal of Prosthodontics, 27(6):560-567.

Abstract

PURPOSE
To compare the accuracy of implant analog positions on complete edentulous maxillary casts made of either dental stone or additive manufactured polymers using a coordinate measuring machine (CMM).
MATERIAL AND METHODS
A completely edentulous maxillary model of a patient with 7 implant analogs was obtained. From this model, two types of casts were duplicated, namely conventional dental stone (CDS) using a custom tray impression technique after splinting (N = 5) and polymer cast using additive manufacturing based on the STL file generated. Polymer casts (N = 20; n = 5 per group) were fabricated using 4 different additive manufacturing technologies (multijet printing-MJP1, direct light processing-DLP, stereolithography-SLA, multijet printing-MJP2). CMM was used to measure the correct position of each implant, and distortion was calculated for each system at x-, y-, and z-axes. Measurements were repeated 3 times per specimen in each axis yielding a total of 546 measurements. Data were analyzed using ANOVA, Sheffé tests, and Bonferroni correction (α = 0.05).
RESULTS
Compared to CMM, the mean distortion (μm) ranged from 22.7 to 74.9, 23.4 to 49.1, and 11.0 to 85.8 in the x-, y-, and z-axes, respectively. CDS method (x-axis: 37.1; z-axis: 27.62) showed a significant difference compared to DLP on the x-axis (22.7) (p = 0.037) and to MJP1 on the z-axis (11.0) (p = 0.003). Regardless of the cast system, x-axes showed more distortion (42.6) compared to y- (34.6) and z-axes (35.97). Among additive manufacturing technologies, MJP2 presented the highest (64.3 ± 83.6), and MJP1 (21.57 ± 16.3) and DLP (27.07 ± 20.23) the lowest distortion, which was not significantly different from CDS (32.3 ± 22.73) (p > 0.05).
CONCLUSION
For the fabrication of the definitive casts for implant prostheses, one of the multijet printing systems and direct light processing additive manufacturing technologies showed similar results to conventional dental stone.
CLINICAL SIGNIFICANCE
Conventional dental stone casts could be accurately duplicated using some of the additive manufacturing technologies tested.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Reconstructive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > General Dentistry
Language:English
Date:July 2018
Deposited On:25 Jan 2019 16:14
Last Modified:28 Aug 2024 03:42
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1059-941X
Additional Information:This is the peer reviewed version of the following article: Journal of Prosthodontics, 27: 560-567, which has been published in final form at https://doi.org/10.1111/jopr.12708. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. (http://www.wileyauthors.com/self-archiving)
OA Status:Green
Publisher DOI:https://doi.org/10.1111/jopr.12708
PubMed ID:29148121

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
46 citations in Web of Science®
47 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

366 downloads since deposited on 25 Jan 2019
78 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications