Header

UZH-Logo

Maintenance Infos

Accuracy of CBCT-based root canal length predetermination using new endodontic planning software compared to measurements performed with an electronic apex locator ex vivo


Tchorz, Jörg Philipp; Wolgin, Michael; Karygianni, Lamprini; Vach, Kirstin; Altenburger, Markus Jörg (2018). Accuracy of CBCT-based root canal length predetermination using new endodontic planning software compared to measurements performed with an electronic apex locator ex vivo. International Journal of Computerized Dentistry, 21(21):323-328.

Abstract

OBJECTIVE
To evaluate the accuracy of the new endodontic planning software (3D Endo Dentsply Sirona) based on cone beam computed tomography (CBCT) to predetermine root canal lengths compared with measurements performed with an electronic apex locator (Raypex 6; VDW) ex vivo.

MATERIALS AND METHODS
CBCT scans of forty extracted human maxillary (n = 20) and mandibular (n = 20) molars were taken, and root canal lengths were predetermined with the 3D Endo software using the apical foramen (AF) and the adjoining cusp as references. Root canal lengths were determined with the Raypex 6 using the same references. To evaluate the accuracy, absolute differences between both methods and the actual root canal length (gold standard) were calculated and statistically analyzed.

RESULTS
Differences between lengths measured with the 3D Endo and the Raypex 6 compared with the gold standard showed no significant differences (P = 0.879). Mean differences were 0.37 mm versus 0.35 mm in the maxillary molars, and 0.30 mm versus 0.31 mm in the mandibular molars. A total of 75.8% (3D Endo) and 79.1% (Raypex 6) of all measurements were within the limits of ± 0.5 mm. Both methods showed a tendency to result in short measurements (P < 0.001).

CONCLUSIONS
Within the limitations of this study, the 3D Endo software enables an accurate three-dimensional (3D) predetermination of root canal lengths.

Abstract

OBJECTIVE
To evaluate the accuracy of the new endodontic planning software (3D Endo Dentsply Sirona) based on cone beam computed tomography (CBCT) to predetermine root canal lengths compared with measurements performed with an electronic apex locator (Raypex 6; VDW) ex vivo.

MATERIALS AND METHODS
CBCT scans of forty extracted human maxillary (n = 20) and mandibular (n = 20) molars were taken, and root canal lengths were predetermined with the 3D Endo software using the apical foramen (AF) and the adjoining cusp as references. Root canal lengths were determined with the Raypex 6 using the same references. To evaluate the accuracy, absolute differences between both methods and the actual root canal length (gold standard) were calculated and statistically analyzed.

RESULTS
Differences between lengths measured with the 3D Endo and the Raypex 6 compared with the gold standard showed no significant differences (P = 0.879). Mean differences were 0.37 mm versus 0.35 mm in the maxillary molars, and 0.30 mm versus 0.31 mm in the mandibular molars. A total of 75.8% (3D Endo) and 79.1% (Raypex 6) of all measurements were within the limits of ± 0.5 mm. Both methods showed a tendency to result in short measurements (P < 0.001).

CONCLUSIONS
Within the limitations of this study, the 3D Endo software enables an accurate three-dimensional (3D) predetermination of root canal lengths.

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Downloads

1 download since deposited on 06 Mar 2019
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Conservative and Preventive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Dentistry (miscellaneous)
Physical Sciences > Computer Science Applications
Language:English
Date:2018
Deposited On:06 Mar 2019 15:22
Last Modified:19 Oct 2022 07:51
Publisher:Quintessence Publishing
ISSN:1463-4201
OA Status:Closed
PubMed ID:30539174