Comparison of gadolinium-enhanced and ferumoxytol-enhanced conventional and UTE-MRA for the depiction of the pulmonary vasculature


Knobloch, Gesine; Colgan, Timothy; Schiebler, Mark L; Johnson, Kevin M; Li, Geng; Schubert, Tilman; Reeder, Scott B; Nagle, Scott K (2019). Comparison of gadolinium-enhanced and ferumoxytol-enhanced conventional and UTE-MRA for the depiction of the pulmonary vasculature. Magnetic Resonance in Medicine, 82(5):1660-1670.

Abstract

PURPOSE

To evaluate the feasibility of ferumoxytol (FE)-enhanced UTE-MRA for depiction of the pulmonary vascular and nonvascular structures.

METHODS
Twenty healthy volunteers underwent contrast-enhanced pulmonary MRA at 3 T during 2 visits, separated by at least 4 weeks. Visit 1: The MRA started with a conventional multiphase 3D T -weighted breath-held spoiled gradient-echo MRA before and after the injection of 0.1 mmol/kg gadobenate dimeglumine (GD). Subsequently, free-breathing GD-UTE-MRA was acquired as a series of 3 flip angles (FAs) (6°, 12°, 18°) to optimize T weighting. Visit 2: After the injection of 4 mg/kg FE, MRA was performed during the steady state, starting with a conventional 3D T -weighted breath-held spoiled gradient-echo MRA and followed by free-breathing FE-UTE-MRA, both at 4 different FAs (6°, 12°, 18°, 24°). The optimal FA for best T contrast was evaluated. Image quality at the optimal FA was compared between methods on a 4-point ordinal scale, using multiphase GD conventional pulmonary MRA (cMRA) as standard of reference.

RESULTS

Flip angle in the range of 18°-24° resulted in best T contrast for FE cMRA and both UTE-MRA techniques (p > .05). At optimized FA, image quality of the vasculature was good/excellent with both FE-UTE-MRA and GD cMRA (98% versus 97%; p = .51). Both UTE techniques provided superior depiction of nonvascular structures compared with either GD-enhanced or FE-enhanced cMRA (p < .001). However, GD-UTE-MRA showed the lowest image quality of the angiogram due to low image contrast.

CONCLUSION

Free-breathing UTE-MRA using FE is feasible for simultaneous assessment of the pulmonary vasculature and nonvascular structures. Patient studies should investigate the clinical utility of free-breathing UTE-MRA for assessment of pulmonary emboli.

Abstract

PURPOSE

To evaluate the feasibility of ferumoxytol (FE)-enhanced UTE-MRA for depiction of the pulmonary vascular and nonvascular structures.

METHODS
Twenty healthy volunteers underwent contrast-enhanced pulmonary MRA at 3 T during 2 visits, separated by at least 4 weeks. Visit 1: The MRA started with a conventional multiphase 3D T -weighted breath-held spoiled gradient-echo MRA before and after the injection of 0.1 mmol/kg gadobenate dimeglumine (GD). Subsequently, free-breathing GD-UTE-MRA was acquired as a series of 3 flip angles (FAs) (6°, 12°, 18°) to optimize T weighting. Visit 2: After the injection of 4 mg/kg FE, MRA was performed during the steady state, starting with a conventional 3D T -weighted breath-held spoiled gradient-echo MRA and followed by free-breathing FE-UTE-MRA, both at 4 different FAs (6°, 12°, 18°, 24°). The optimal FA for best T contrast was evaluated. Image quality at the optimal FA was compared between methods on a 4-point ordinal scale, using multiphase GD conventional pulmonary MRA (cMRA) as standard of reference.

RESULTS

Flip angle in the range of 18°-24° resulted in best T contrast for FE cMRA and both UTE-MRA techniques (p > .05). At optimized FA, image quality of the vasculature was good/excellent with both FE-UTE-MRA and GD cMRA (98% versus 97%; p = .51). Both UTE techniques provided superior depiction of nonvascular structures compared with either GD-enhanced or FE-enhanced cMRA (p < .001). However, GD-UTE-MRA showed the lowest image quality of the angiogram due to low image contrast.

CONCLUSION

Free-breathing UTE-MRA using FE is feasible for simultaneous assessment of the pulmonary vasculature and nonvascular structures. Patient studies should investigate the clinical utility of free-breathing UTE-MRA for assessment of pulmonary emboli.

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Neuroradiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:1 November 2019
Deposited On:26 Jul 2019 12:28
Last Modified:25 Sep 2019 00:38
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0740-3194
OA Status:Closed
Publisher DOI:https://doi.org/10.1002/mrm.27853
PubMed ID:31228293

Download

Full text not available from this repository.
View at publisher

Get full-text in a library