Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments


Phi Van, Valerie; Reiner, Caecilia S; Klarhoefer, Markus; Ciritsis, Alexander; Eberhardt, Christian; Wurnig, Moritz C; Rossi, Cristina (2019). Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments. NMR in Biomedicine:e4159.

Abstract

Water flow in partially oriented intravoxel compartments mimics an anisotropic fast-diffusion regime, which contributes to the signal attenuation in diffusion-weighted images. In the abdominal organs, this flow may reflect physiological fluid movements (eg, tubular urine flow in kidneys, or bile flow through the liver) and have a clinical relevance. This study investigated the influence of anisotropic intravoxel water flow on diffusion tensor imaging (DTI) of the abdominal organs. Diffusion-weighted images were acquired in five healthy volunteers using an EPI sequence with diffusion preparation (TR/TE: 1000 ms/71 ms; b-values: 0, 10, 20, 40, 70, 120, 250, 450, 700, 1000 s/mm ; 12 noncollinear diffusion-encoding directions). DTI of liver and kidneys was performed assuming (i) monoexponential decay of the diffusion-weighted signal, and (ii) accounting for potential anisotropy of the fast-diffusion compartments using a tensorial generalization of the IVIM model. Additionally, potential dependency of the metrics of the tensors from the anatomical location was evaluated. Significant differences in the metrics of the diffusion tensor (DT) were found in both liver and kidneys when comparing the two models. In both organs, the trace and the fractional anisotropy of the DT were significantly higher in the monoexponential model than when accounting for perfusion. The comparison of areas of the liver proximal to the hilum with distal regions and of renal cortex with the medulla also proved a location dependency of the size of the fast-diffusion compartments. Pseudo-diffusion correction in DTI enables the assessment of the solid parenchyma regardless of the organ perfusion or other pseudo-diffusive fluid movements. This may have a clinical relevance in the assessment of parenchymal pathologies (eg, liver fibrosis). The fast pseudo-diffusion components present a detectable anisotropy, which may reflect the hepatic microcirculation or other sources of mesoscopic fluid movement in the abdominal organs.

Abstract

Water flow in partially oriented intravoxel compartments mimics an anisotropic fast-diffusion regime, which contributes to the signal attenuation in diffusion-weighted images. In the abdominal organs, this flow may reflect physiological fluid movements (eg, tubular urine flow in kidneys, or bile flow through the liver) and have a clinical relevance. This study investigated the influence of anisotropic intravoxel water flow on diffusion tensor imaging (DTI) of the abdominal organs. Diffusion-weighted images were acquired in five healthy volunteers using an EPI sequence with diffusion preparation (TR/TE: 1000 ms/71 ms; b-values: 0, 10, 20, 40, 70, 120, 250, 450, 700, 1000 s/mm ; 12 noncollinear diffusion-encoding directions). DTI of liver and kidneys was performed assuming (i) monoexponential decay of the diffusion-weighted signal, and (ii) accounting for potential anisotropy of the fast-diffusion compartments using a tensorial generalization of the IVIM model. Additionally, potential dependency of the metrics of the tensors from the anatomical location was evaluated. Significant differences in the metrics of the diffusion tensor (DT) were found in both liver and kidneys when comparing the two models. In both organs, the trace and the fractional anisotropy of the DT were significantly higher in the monoexponential model than when accounting for perfusion. The comparison of areas of the liver proximal to the hilum with distal regions and of renal cortex with the medulla also proved a location dependency of the size of the fast-diffusion compartments. Pseudo-diffusion correction in DTI enables the assessment of the solid parenchyma regardless of the organ perfusion or other pseudo-diffusive fluid movements. This may have a clinical relevance in the assessment of parenchymal pathologies (eg, liver fibrosis). The fast pseudo-diffusion components present a detectable anisotropy, which may reflect the hepatic microcirculation or other sources of mesoscopic fluid movement in the abdominal organs.

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 21 Aug 2019
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Life Sciences > Molecular Medicine
Health Sciences > Radiology, Nuclear Medicine and Imaging
Physical Sciences > Spectroscopy
Language:English
Date:9 August 2019
Deposited On:21 Aug 2019 10:13
Last Modified:29 Jul 2020 11:11
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0952-3480
OA Status:Closed
Publisher DOI:https://doi.org/10.1002/nbm.4159
PubMed ID:31397037

Download

Closed Access: Download allowed only for UZH members