Thamsen, Bente; Gülan, Utku; Wiegmann, Lena; Loosli, Christian; Schmid Daners, Marianne; Kurtcuoglu, Vartan; Holzner, Markus; Meboldt, Mirko (2020). Assessment of the flow field in the heartmate 3 using three-dimensional particle tracking velocimetry and comparison to computational fluid dynamics. ASAIO Journal, 66(2):173-182.

Abstract

Flow fields in rotary blood pumps (RBPs) have a significant influence on hemocompatibility. Because flow characteristics vary with flow rate, different operating conditions play a role. Furthermore, turbulence is crucial in the evaluation of blood damage potential, but the level of turbulence in implantable RBPs is still unknown. In this study, we addressed both research aspects and for the first time measured turbulent flow fields in the HeartMate 3 (HM3) at different operating flows. The averaged, three-dimensional velocity field including fluctuating velocity components in a HM3 with a transparent lower housing was measured using three-dimensional particle tracking velocimetry (3D-PTV). In vitro results were compared with computational fluid dynamic (CFD) simulations for two flow cases, representing the lower and upper physiologic flow range (2.7 and 5.7 L/min), using two different turbulence models that account for fluctuating velocity fields: the k-ω shear stress transport and the Reynolds stress model (RSM). The measurements revealed higher mean and turbulent kinetic energies (TKEs) for the low-flow condition especially within the gap beneath the impeller. Computed mean fields agree well with 3D-PTV for both models, but the RSM predicts the TKE levels better than the k-ω model. Computational fluid dynamic results further show wall shear stresses higher than 150 Pa, a commonly used damage threshold, in the bottom gap for the lower flow condition. In conclusion, the low-flow condition was found to be more prone to blood damage. Furthermore, CFD predictions for turbulence must be carefully experimentally validated.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Physiology
07 Faculty of Science > Institute of Physiology

04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
Dewey Decimal Classification:570 Life sciences; biology
610 Medicine & health
Scopus Subject Areas:Life Sciences > Biophysics
Physical Sciences > Bioengineering
Physical Sciences > Biomaterials
Physical Sciences > Biomedical Engineering
Language:English
Date:1 February 2020
Deposited On:26 Aug 2020 17:49
Last Modified:02 Mar 2025 04:40
Publisher:Lippincott Williams & Wilkins
ISSN:1058-2916
OA Status:Hybrid
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1097/MAT.0000000000000987
PubMed ID:30883404
Download PDF  'Assessment of the flow field in the heartmate 3 using three-dimensional particle tracking velocimetry and comparison to computational fluid dynamics'.
Preview
  • Content: Published Version
  • Language: English

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
20 citations in Web of Science®
20 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

163 downloads since deposited on 26 Aug 2020
51 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications