Variability of Manual Segmentation of the Prostate in Axial T2-weighted MRI: A Multi-Reader Study


Becker, Anton S; Chaitanya, Krishna; Schawkat, Khoschy; Mühlematter, Urs J; Hötker, Andreas M; Konukoglu, Ender; Donati, Olivio F (2019). Variability of Manual Segmentation of the Prostate in Axial T2-weighted MRI: A Multi-Reader Study. European Journal of Radiology, 121:108716.

Abstract

Purpose
To evaluate the interreader variability in prostate and seminal vesicle (SV) segmentation on T2w MRI.
Methods
Six readers segmented the peripheral zone (PZ), transitional zone (TZ) and SV slice-wise on axial T2w prostate MRI examinations of n = 80 patients.
Twenty different similarity scores, including dice score (DS), Hausdorff distance (HD) and volumetric similarity coefficient (VS), were computed with the VISCERAL EvaluateSegmentation software for all structures combined and separately for the whole gland (WG = PZ + TZ), TZ and SV. Differences between base, midgland and apex were evaluated with DS slice-wise.
Descriptive statistics for similarity scores were computed. Wilcoxon testing to evaluate differences of DS, HD and VS was performed.
Results
Overall segmentation variability was good with a mean DS of 0.859 (±SD = 0.0542), HD of 36.6 (±34.9 voxels) and VS of 0.926 (±0.065). The WG showed a DS, HD and VS of 0.738 (±0.144), 36.2 (±35.6 vx) and 0.853 (±0.143), respectively. The TZ showed generally lower variability with a DS of 0.738 (±0.144), HD of 24.8 (±16 vx) and VS of 0.908 (±0.126). The lowest variability was found for the SV with DS of 0.884 (±0.0407), HD of 17 (±10.9 vx) and VS of 0.936 (±0.0509). We found a markedly lower DS of the segmentations in the apex (0.85 ± 0.12) compared to the base (0.87 ± 0.10, p < 0.01) and the midgland (0.89 ± 0.10, p < 0.001).
Conclusions
We report baseline values for interreader variability of prostate and SV segmentation on T2w MRI. Variability was highest in the apex, lower in the base, and lowest in the midgland.

Abstract

Purpose
To evaluate the interreader variability in prostate and seminal vesicle (SV) segmentation on T2w MRI.
Methods
Six readers segmented the peripheral zone (PZ), transitional zone (TZ) and SV slice-wise on axial T2w prostate MRI examinations of n = 80 patients.
Twenty different similarity scores, including dice score (DS), Hausdorff distance (HD) and volumetric similarity coefficient (VS), were computed with the VISCERAL EvaluateSegmentation software for all structures combined and separately for the whole gland (WG = PZ + TZ), TZ and SV. Differences between base, midgland and apex were evaluated with DS slice-wise.
Descriptive statistics for similarity scores were computed. Wilcoxon testing to evaluate differences of DS, HD and VS was performed.
Results
Overall segmentation variability was good with a mean DS of 0.859 (±SD = 0.0542), HD of 36.6 (±34.9 voxels) and VS of 0.926 (±0.065). The WG showed a DS, HD and VS of 0.738 (±0.144), 36.2 (±35.6 vx) and 0.853 (±0.143), respectively. The TZ showed generally lower variability with a DS of 0.738 (±0.144), HD of 24.8 (±16 vx) and VS of 0.908 (±0.126). The lowest variability was found for the SV with DS of 0.884 (±0.0407), HD of 17 (±10.9 vx) and VS of 0.936 (±0.0509). We found a markedly lower DS of the segmentations in the apex (0.85 ± 0.12) compared to the base (0.87 ± 0.10, p < 0.01) and the midgland (0.89 ± 0.10, p < 0.001).
Conclusions
We report baseline values for interreader variability of prostate and SV segmentation on T2w MRI. Variability was highest in the apex, lower in the base, and lowest in the midgland.

Statistics

Citations

Dimensions.ai Metrics
12 citations in Web of Science®
14 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

80 downloads since deposited on 01 Nov 2019
62 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Uncontrolled Keywords:Radiology Nuclear Medicine and imaging, General Medicine
Language:English
Date:1 December 2019
Deposited On:01 Nov 2019 12:43
Last Modified:26 Jan 2022 22:54
Publisher:Elsevier
ISSN:0720-048X
OA Status:Green
Publisher DOI:https://doi.org/10.1016/j.ejrad.2019.108716

Download

Green Open Access

Download PDF  'Variability of Manual Segmentation of the Prostate in Axial T2-weighted MRI: A Multi-Reader Study'.
Preview
Content: Accepted Version
Filetype: PDF
Size: 2MB
View at publisher
Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)