Sonographic prediction of macrosomia cannot be improved by combination with pregnancy-specific characteristics


Balsyte, D; Schäffer, L; Burkhardt, T; Wisser, J; Kurmanavicius, J (2009). Sonographic prediction of macrosomia cannot be improved by combination with pregnancy-specific characteristics. Ultrasound in Obstetrics and Gynecology, 33(4):453-458.

Abstract

OBJECTIVE: To evaluate the predictive value of a combination of sonographic, clinical and demographic data for detecting fetal macrosomia compared to ultrasound fetal weight estimation alone. METHODS: Retrospective cohort data were obtained from 1062 pregnancies in an unselected population. Estimated fetal sonographic weight was obtained within the last week prior to delivery. Two different combination models-published by Mazouni et al. and Nahum and Stanislaw-were employed to predict the presence of macrosomia at birth in these infants. Receiver-operating characteristics (ROC) curves were generated to compare the prediction of macrosomia when using different observation methods and sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were calculated. RESULTS: Macrosomia (birth weight >/= 4000 g) was present in 135/1062 (12.7%) newborns. ROC curve analysis revealed the prediction of macrosomia using ultrasound alone to be significantly superior to the combined method of Mazouni et al. (area under the curve (AUC) 0.922, 95% CI 0.902-0.943 vs. 0.747, 95% CI 0.700-0.794, respectively; P < 0.0005), whereas the performance of the Nahum and Stanislaw equation was similar but not superior to ultrasound alone (AUC 0.895, 95% CI 0.839-0.950 vs. 0.912, 95% CI 0.867-0.958, respectively; P > 0.05). The accuracy of macrosomia prediction was similar for ultrasound alone and the Nahum and Stanislaw equation ( approximately 90%), whereas the nomogram of Mazouni et al. reached only 51.7% accuracy (using a probability cut-off level of 50%). The NPV was found to be over 90% for all methods. CONCLUSIONS: Combination of sonographic estimates with clinical and demographic variables does not improve the prediction of macrosomia at delivery in comparison with a routine ultrasound scan within a week before delivery, at least in unselected populations. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Abstract

OBJECTIVE: To evaluate the predictive value of a combination of sonographic, clinical and demographic data for detecting fetal macrosomia compared to ultrasound fetal weight estimation alone. METHODS: Retrospective cohort data were obtained from 1062 pregnancies in an unselected population. Estimated fetal sonographic weight was obtained within the last week prior to delivery. Two different combination models-published by Mazouni et al. and Nahum and Stanislaw-were employed to predict the presence of macrosomia at birth in these infants. Receiver-operating characteristics (ROC) curves were generated to compare the prediction of macrosomia when using different observation methods and sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were calculated. RESULTS: Macrosomia (birth weight >/= 4000 g) was present in 135/1062 (12.7%) newborns. ROC curve analysis revealed the prediction of macrosomia using ultrasound alone to be significantly superior to the combined method of Mazouni et al. (area under the curve (AUC) 0.922, 95% CI 0.902-0.943 vs. 0.747, 95% CI 0.700-0.794, respectively; P < 0.0005), whereas the performance of the Nahum and Stanislaw equation was similar but not superior to ultrasound alone (AUC 0.895, 95% CI 0.839-0.950 vs. 0.912, 95% CI 0.867-0.958, respectively; P > 0.05). The accuracy of macrosomia prediction was similar for ultrasound alone and the Nahum and Stanislaw equation ( approximately 90%), whereas the nomogram of Mazouni et al. reached only 51.7% accuracy (using a probability cut-off level of 50%). The NPV was found to be over 90% for all methods. CONCLUSIONS: Combination of sonographic estimates with clinical and demographic variables does not improve the prediction of macrosomia at delivery in comparison with a routine ultrasound scan within a week before delivery, at least in unselected populations. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Statistics

Citations

Dimensions.ai Metrics
26 citations in Web of Science®
26 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

315 downloads since deposited on 03 Feb 2010
9 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Obstetrics
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiological and Ultrasound Technology
Health Sciences > Reproductive Medicine
Health Sciences > Radiology, Nuclear Medicine and Imaging
Health Sciences > Obstetrics and Gynecology
Uncontrolled Keywords:Obstetrics and Gynaecology, Radiological and Ultrasound Technology, Radiology Nuclear Medicine and imaging, Reproductive Medicine, General Medicine
Language:English
Date:2009
Deposited On:03 Feb 2010 07:43
Last Modified:03 Oct 2023 01:36
Publisher:Wiley-Blackwell
ISSN:0960-7692
Additional Information:The definitive version is available at www.blackwell-synergy.com
OA Status:Green
Publisher DOI:https://doi.org/10.1002/uog.6282
PubMed ID:19266500
  • Content: Accepted Version