Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Implant-Retained Overdentures Using an Attachment with True-Alignment Correction: A Case Series

Srinivasan, Murali; Kalberer, Nicole; Maniewicz, Sabrina; Müller, Frauke (2019). Implant-Retained Overdentures Using an Attachment with True-Alignment Correction: A Case Series. International Journal of Prosthodontics, 32(6):482-496.

Abstract

Implant parallelism is considered a cardinal criterion for the successful rehabilitation of edentulous jaws with implant-retained overdentures (IODs), especially if freestanding anchorage systems (unsplinted attachments) are employed. This report aimed to demonstrate the successful use of a novel IOD attachment with a true-alignment capability in complex cases with large inter-implant angular discrepancies. The report further aimed to highlight the use of a novel polyetherketoneketone (PEKK) framework as a reinforcement material for fabricating a completely metal-free IOD. Although some freestanding attachments exploit their geometric form and/or use various retentive inserts to compensate for inter-implant angular discrepancies, a true-alignment correction is seldom achieved. The CM LOC FLEX (Cendres+Métaux attachment provides a true alignment correction and produces parallelism between implants in clinical situations where the implants are not parallel to one another. The functionality of the CM LOC FLEX was described in this case report for two different clinical situations: a conventional mandibular IOD retained by two implants, and a maxillary IOD retained by four implants. Both cases involved a complex clinical situation with compromised implant parallelism. The CM LOC FLEX abutment has a true-alignment correction mechanism that can be advantageous in clinical situations where the inter-implant axial alignments are not parallel. PEKK frameworks are lightweight, strong, and can be esthetic substitutes for conventional metal frameworks. However, well-designed clinical studies are further needed to assess the clinical performance as well as the maintenance requirements of the illustrated novel attachment and the PEKK framework before advocating them as validated and standard protocols.

Additional indexing

Item Type:Journal Article, refereed, further contribution
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Klinik für Allgemein-, Behinderten- und Seniorenzahnmedizin
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Oral Surgery
Language:English
Date:November 2019
Deposited On:13 Jan 2020 15:54
Last Modified:22 Dec 2024 02:38
Publisher:Quintessence Publishing
ISSN:0893-2174
OA Status:Closed
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.11607/ijp.6469
PubMed ID:31664264

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
5 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 13 Jan 2020
0 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications