Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations

Moura, Renata Vasconcellos; Kojima, Alberto Noriyuki; Saraceni, Cintia Helena Coury; Bassolli, Lucas; Balducci, Ivan; Özcan, Mutlu; Mesquita, Alfredo Mikail Melo (2019). Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations. Journal of Prosthodontics, 28(2):e530-e535.

Abstract

PURPOSE
The increased use of CAD systems can generate doubt about the accuracy of digital impressions for angulated implants. The aim of this study was to evaluate the accuracy of different impression techniques, two conventional and one digital, for implants with and without angulation.
MATERIALS AND METHODS
We used a polyurethane cast that simulates the human maxilla according to ASTM F1839, and 6 tapered implants were installed with external hexagonal connections to simulate tooth positions 17, 15, 12, 23, 25, and 27. Implants 17 and 23 were placed with 15° of mesial angulation and distal angulation, respectively. Mini cone abutments were installed on these implants with a metal strap 1 mm in height. Conventional and digital impression procedures were performed on the maxillary master cast, and the implants were separated into 6 groups based on the technique used and measurement type: G1 - control, G2 - digital impression, G3 - conventional impression with an open tray, G4 - conventional impression with a closed tray, G5 - conventional impression with an open tray and a digital impression, and G6 - conventional impression with a closed tray and a digital impression. A statistical analysis was performed using two-way repeated measures ANOVA to compare the groups, and a Kruskal-Wallis test was conducted to analyze the accuracy of the techniques.
RESULTS
No significant difference in the accuracy of the techniques was observed between the groups. Therefore, no differences were found among the conventional impression and the combination of conventional and digital impressions, and the angulation of the implants did not affect the accuracy of the techniques.
CONCLUSIONS
All of the techniques exhibited trueness and had acceptable precision. The variation of the angle of the implants did not affect the accuracy of the techniques.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Reconstructive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > General Dentistry
Language:English
Date:February 2019
Deposited On:07 Feb 2020 14:39
Last Modified:05 Sep 2024 03:39
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1059-941X
Additional Information:This is the peer reviewed version of the following article: Moura, Renata Vasconcellos; Kojima, Alberto Noriyuki; Saraceni, Cintia Helena Coury; Bassolli, Lucas; Balducci, Ivan; Özcan, Mutlu; Mesquita, Alfredo Mikail Melo (2019), which has been published in final form at https://doi.org/10.1111/jopr.12799. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. (http://www.wileyauthors.com/self-archiving)
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/jopr.12799
PubMed ID:29717518

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
29 citations in Web of Science®
34 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

3 downloads since deposited on 07 Feb 2020
1 download since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications