Pellegrini, Costanza; Rheude, Tobias; Trenkwalder, Teresa; Mayr, N Patrick; Michel, Jonathan; Kastrati, Adnan; Schunkert, Heribert; Kasel, Albert M; Joner, Michael; Hengstenberg, Christian; Husser, Oliver (2019). One-year clinical outcome with a novel self-expanding transcatheter heart valve. Catheterization and Cardiovascular Interventions, 94(6):783-792.

Abstract

OBJECTIVES

To evaluate 1-year outcome using the ACURATE neo (Symetis S.A., a Boston Scientific Company, Ecublens, Switzerland) according to the updated Valve Academic Research Consortium (VARC-2) with emphasis on the composite endpoints "clinical efficacy after 30 days" and "time-related valve safety".

BACKGROUND

Initial reports on the clinical performance of patients treated with the ACURATE neo are promising; however, information regarding one-year outcome is scarce, especially with regard to the composite endpoints proposed by the VARC-2.

METHODS

One hundred and fifty one consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) with the ACURATE neo for severe aortic valve stenosis were enrolled. Data were prospectively collected and event rates during follow-up were calculated as the Kaplan-Meier estimates.

RESULTS

Mean age was 81.1 ± 5.9 years and 49.7% (75/151) were female with a median logistic EuroScore of 13.8% [8.2-20.5]. Device success was achieved in 88.1% (133/151) and procedure related mortality was 0.7% (1/151). At one-year, all-cause mortality was 3.3% (5/151), while permanent pacemaker implantation occurred in 12.7% (19/151) of patients. The "clinical efficacy after 30 days" was observed in 24.8% (37/151), where the main contributor was symptom worsening in 14.8% (22/151) of cases. "Time-related valve safety" occurred in 22.0% (33/151) with structural valve deterioration as main contributor in 10.7% (16/151) of cases.

CONCLUSIONS

Using the ACURATE neo, we found a favorable safety profile with low all-cause mortality at 1 year. The reported VARC-2 defined composite endpoints at 1 year reveal low rates of "clinical efficacy after 30 days" and "time-related valve safety".

Abstract

OBJECTIVES

To evaluate 1-year outcome using the ACURATE neo (Symetis S.A., a Boston Scientific Company, Ecublens, Switzerland) according to the updated Valve Academic Research Consortium (VARC-2) with emphasis on the composite endpoints "clinical efficacy after 30 days" and "time-related valve safety".

BACKGROUND

Initial reports on the clinical performance of patients treated with the ACURATE neo are promising; however, information regarding one-year outcome is scarce, especially with regard to the composite endpoints proposed by the VARC-2.

METHODS

One hundred and fifty one consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) with the ACURATE neo for severe aortic valve stenosis were enrolled. Data were prospectively collected and event rates during follow-up were calculated as the Kaplan-Meier estimates.

RESULTS

Mean age was 81.1 ± 5.9 years and 49.7% (75/151) were female with a median logistic EuroScore of 13.8% [8.2-20.5]. Device success was achieved in 88.1% (133/151) and procedure related mortality was 0.7% (1/151). At one-year, all-cause mortality was 3.3% (5/151), while permanent pacemaker implantation occurred in 12.7% (19/151) of patients. The "clinical efficacy after 30 days" was observed in 24.8% (37/151), where the main contributor was symptom worsening in 14.8% (22/151) of cases. "Time-related valve safety" occurred in 22.0% (33/151) with structural valve deterioration as main contributor in 10.7% (16/151) of cases.

CONCLUSIONS

Using the ACURATE neo, we found a favorable safety profile with low all-cause mortality at 1 year. The reported VARC-2 defined composite endpoints at 1 year reveal low rates of "clinical efficacy after 30 days" and "time-related valve safety".

Statistics

Citations

Dimensions.ai Metrics
2 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:15 November 2019
Deposited On:07 Feb 2020 16:17
Last Modified:07 Feb 2020 16:18
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1522-1946
OA Status:Closed
Publisher DOI:https://doi.org/10.1002/ccd.28144
PubMed ID:30801906

Download

Full text not available from this repository.
View at publisher

Get full-text in a library