Header

UZH-Logo

Maintenance Infos

Multiple measures derived from 3D photonic body scans improve predictions of fat and muscle mass in young Swiss men


Sager, Roman; Güsewell, Sabine; Rühli, Frank; Bender, Nicole; Staub, Kaspar (2020). Multiple measures derived from 3D photonic body scans improve predictions of fat and muscle mass in young Swiss men. PLoS ONE, 15(6):e0234552.

Abstract

Introduction

Digital tools like 3D laser-based photonic scanners, which can assess external anthropometric measurements for population based studies, and predict body composition, are gaining in importance. Here we focus on a) systematic deviation between manually determined and scanned standard measurements, b) differences regarding the strength of association between these standard measurements and body composition, and c) improving these predictions of body composition by considering additional scan measurements.
Methods

We analysed 104 men aged 19–23. Bioelectrical Impedance Analysis was used to estimate whole body fat mass, visceral fat mass and skeletal muscle mass (SMM). For the 3D body scans, an Anthroscan VITUSbodyscan was used to automatically obtain 90 body shape measurements. Manual anthropometric measurements (height, weight, waist circumference) were also taken.
Results

Scanned and manually measured height, waist circumference, waist-to-height-ratio, and BMI were strongly correlated (Spearman Rho>0.96), however we also found systematic differences. When these variables were used to predict body fat or muscle mass, explained variation and prediction standard errors were similar between scanned and manual measurements. The univariable predictions performed well for both visceral fat (r2 up to 0.92) and absolute fat mass (AFM, r2 up to 0.87) but not for SMM (r2 up to 0.54). Of the 90 body scanner measures used in the multivariable prediction models, belly circumference and middle hip circumference were the most important predictors of body fat content. Stepwise forward model selection using the AIC criterion showed that the best predictive power (r2 up to 0.99) was achieved with models including 49 scanner measurements.
Conclusion

The use of a 3D full body scanner produced results that strongly correlate to manually measured anthropometric measures. Predictions were improved substantially by including multiple measurements, which can only be obtained with a 3D body scanner, in the models.

Abstract

Introduction

Digital tools like 3D laser-based photonic scanners, which can assess external anthropometric measurements for population based studies, and predict body composition, are gaining in importance. Here we focus on a) systematic deviation between manually determined and scanned standard measurements, b) differences regarding the strength of association between these standard measurements and body composition, and c) improving these predictions of body composition by considering additional scan measurements.
Methods

We analysed 104 men aged 19–23. Bioelectrical Impedance Analysis was used to estimate whole body fat mass, visceral fat mass and skeletal muscle mass (SMM). For the 3D body scans, an Anthroscan VITUSbodyscan was used to automatically obtain 90 body shape measurements. Manual anthropometric measurements (height, weight, waist circumference) were also taken.
Results

Scanned and manually measured height, waist circumference, waist-to-height-ratio, and BMI were strongly correlated (Spearman Rho>0.96), however we also found systematic differences. When these variables were used to predict body fat or muscle mass, explained variation and prediction standard errors were similar between scanned and manual measurements. The univariable predictions performed well for both visceral fat (r2 up to 0.92) and absolute fat mass (AFM, r2 up to 0.87) but not for SMM (r2 up to 0.54). Of the 90 body scanner measures used in the multivariable prediction models, belly circumference and middle hip circumference were the most important predictors of body fat content. Stepwise forward model selection using the AIC criterion showed that the best predictive power (r2 up to 0.99) was achieved with models including 49 scanner measurements.
Conclusion

The use of a 3D full body scanner produced results that strongly correlate to manually measured anthropometric measures. Predictions were improved substantially by including multiple measurements, which can only be obtained with a 3D body scanner, in the models.

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
4 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

23 downloads since deposited on 12 Jun 2020
7 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Evolutionary Medicine
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Life Sciences > General Biochemistry, Genetics and Molecular Biology
Life Sciences > General Agricultural and Biological Sciences
Health Sciences > Multidisciplinary
Language:English
Date:11 June 2020
Deposited On:12 Jun 2020 05:36
Last Modified:27 Jan 2022 02:05
Publisher:Public Library of Science (PLoS)
ISSN:1932-6203
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1371/journal.pone.0234552
PubMed ID:32525949
  • Content: Published Version
  • Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)