Background

Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference treatment plans.
Methods

Fifty-two patients treated on a ViewRay MRIdian Linac were included in this retrospective study. In total 238 online-adapted plans were analyzed, which were optimized with either changing of the segment weights (n = 85) or full re-optimization (n = 153). Five different treatment sites were evaluated: prostate, abdomen, liver, lung and pelvis. Dosimetric parameters of gross tumor volume (GTV), planning target volume (PTV), 2 cm ring around the PTV and organs at risk (OARs) were considered. The Wilcoxon signed-rank test was used to assess differences between online-adapted and reference treatment plans, p < 0.05 was considered significant.
Results

The average duration of the online adaptation, consisting of contour editing, plan optimization and quality assurance (QA), was 24 ± 6 min. The GTV was slightly larger (average ± SD: 1.9% ± 9.0%) in the adapted plans than in the reference plans (p < 0.001). GTV-D95% exhibited no significant changes when considering all plans, but GTV-D2% increased by 0.40% ± 1.5% on average (p < 0.001). There was a very small yet significant decrease in GTV-coverage for the abdomen plans. The ring Dmean increased on average by 1.0% ± 3.6% considering all plans (p < 0.001). There was a significant reduction of the dose to the rectum of 4.7% ± 16% on average (p < 0.001) for prostate plans.
Conclusions

Dosimetric quality of online-adapted plans was comparable to reference treatment plans and OAR dose was either comparable or decreased, depending on treatment site. However, dose spillage was slightly increased.

Abstract

Background

Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference treatment plans.
Methods

Fifty-two patients treated on a ViewRay MRIdian Linac were included in this retrospective study. In total 238 online-adapted plans were analyzed, which were optimized with either changing of the segment weights (n = 85) or full re-optimization (n = 153). Five different treatment sites were evaluated: prostate, abdomen, liver, lung and pelvis. Dosimetric parameters of gross tumor volume (GTV), planning target volume (PTV), 2 cm ring around the PTV and organs at risk (OARs) were considered. The Wilcoxon signed-rank test was used to assess differences between online-adapted and reference treatment plans, p < 0.05 was considered significant.
Results

The average duration of the online adaptation, consisting of contour editing, plan optimization and quality assurance (QA), was 24 ± 6 min. The GTV was slightly larger (average ± SD: 1.9% ± 9.0%) in the adapted plans than in the reference plans (p < 0.001). GTV-D95% exhibited no significant changes when considering all plans, but GTV-D2% increased by 0.40% ± 1.5% on average (p < 0.001). There was a very small yet significant decrease in GTV-coverage for the abdomen plans. The ring Dmean increased on average by 1.0% ± 3.6% considering all plans (p < 0.001). There was a significant reduction of the dose to the rectum of 4.7% ± 16% on average (p < 0.001) for prostate plans.
Conclusions

Dosimetric quality of online-adapted plans was comparable to reference treatment plans and OAR dose was either comparable or decreased, depending on treatment site. However, dose spillage was slightly increased.

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

4 downloads since deposited on 17 Dec 2020
4 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Radiation Oncology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Oncology
Health Sciences > Radiology, Nuclear Medicine and Imaging
Uncontrolled Keywords:Radiotherapy, MR-linac, Online-adaptive radiation therapy, MR-guided, MRgRT, Online, Adaptive, Planning, SBRT
Language:English
Date:1 December 2020
Deposited On:17 Dec 2020 11:31
Last Modified:26 Jan 2021 21:25
Publisher:BioMed Central
ISSN:1748-717X
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1186/s13014-020-01641-0
PubMed ID:32825848
Project Information:
  • : FunderBaugarten Foundation Zurich
  • : Grant IDKW/MR 2817
  • : Project Title
  • : FunderSNF R’Equip program
  • : Grant ID326030_177080 / 1
  • : Project Title

Download

Gold Open Access

Download PDF  'Treatment plan quality during online adaptive re-planning'.
Preview
Content: Published Version
Language: English
Filetype: PDF
Size: 743kB
View at publisher
Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)