Pretreatment central quality control for craniospinal irradiation in non-metastatic medulloblastoma : First experiences of the German radiotherapy quality control panel in the SIOP PNET5 MB trial


Dietzsch, Stefan; Braesigk, Annett; Seidel, Clemens; Remmele, Julia; Kitzing, Ralf; Schlender, Tina; Mynarek, Martin; Geismar, Dirk; Jablonska, Karolina; Schwarz, Rudolf; Pazos, Montserrat; Walser, Marc; Frick, Silke; Gurtner, Kristin; Matuschek, Christiane; Harrabi, Semi Ben; Glück, Albrecht; Lewitzki, Victor; Dieckmann, Karin; Benesch, Martin; Gerber, Nicolas U; Rutkowski, Stefan; Timmermann, Beate; Kortmann, Rolf-Dieter (2020). Pretreatment central quality control for craniospinal irradiation in non-metastatic medulloblastoma : First experiences of the German radiotherapy quality control panel in the SIOP PNET5 MB trial. Strahlentherapie und Onkologie:Epub ahead of print.

Abstract

PURPOSE

Several studies have demonstrated the negative impact of radiotherapy protocol deviations on tumor control in medulloblastoma. In the SIOP PNET5 MB trial, a pretreatment radiotherapy quality control (RT-QC) program was introduced. A first analysis for patients enrolled in Germany, Switzerland and Austria with focus on types of deviations in the initial plan proposals and review criteria for modern radiation technologies was performed.

METHODS AND PATIENTS

Sixty-nine craniospinal irradiation (CSI) plans were available for detailed analyses. RT-QC was performed according to protocol definitions on dose uniformity. Because of the lack of definitions for high-precision 3D conformal radiotherapy within the protocol, additional criteria for RT-QC on delineation and coverage of clinical target volume (CTV) and planning target volume (PTV) were defined and evaluated.

RESULTS

Target volume (CTV/PTV) deviations occurred in 49.3% of initial CSI plan proposals (33.3% minor, 15.9% major). Dose uniformity deviations were less frequent (43.5%). Modification of the RT plan was recommended in 43.5% of CSI plans. Unacceptable RT plans were predominantly related to incorrect target delineation rather than dose uniformity. Unacceptable plans were negatively correlated to the number of enrolled patients per institution with a cutoff of 5 patients (p = 0.001).

CONCLUSION

This prospective pretreatment individual case review study revealed a high rate of deviations and emphasizes the strong need of pretreatment RT-QC in clinical trials for medulloblastoma. Furthermore, the experiences point out the necessity of new RT-QC criteria for high-precision CSI techniques.

Abstract

PURPOSE

Several studies have demonstrated the negative impact of radiotherapy protocol deviations on tumor control in medulloblastoma. In the SIOP PNET5 MB trial, a pretreatment radiotherapy quality control (RT-QC) program was introduced. A first analysis for patients enrolled in Germany, Switzerland and Austria with focus on types of deviations in the initial plan proposals and review criteria for modern radiation technologies was performed.

METHODS AND PATIENTS

Sixty-nine craniospinal irradiation (CSI) plans were available for detailed analyses. RT-QC was performed according to protocol definitions on dose uniformity. Because of the lack of definitions for high-precision 3D conformal radiotherapy within the protocol, additional criteria for RT-QC on delineation and coverage of clinical target volume (CTV) and planning target volume (PTV) were defined and evaluated.

RESULTS

Target volume (CTV/PTV) deviations occurred in 49.3% of initial CSI plan proposals (33.3% minor, 15.9% major). Dose uniformity deviations were less frequent (43.5%). Modification of the RT plan was recommended in 43.5% of CSI plans. Unacceptable RT plans were predominantly related to incorrect target delineation rather than dose uniformity. Unacceptable plans were negatively correlated to the number of enrolled patients per institution with a cutoff of 5 patients (p = 0.001).

CONCLUSION

This prospective pretreatment individual case review study revealed a high rate of deviations and emphasizes the strong need of pretreatment RT-QC in clinical trials for medulloblastoma. Furthermore, the experiences point out the necessity of new RT-QC criteria for high-precision CSI techniques.

Statistics

Citations

Altmetrics

Downloads

2 downloads since deposited on 27 Jan 2021
2 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Health Sciences > Oncology
Language:English
Date:23 November 2020
Deposited On:27 Jan 2021 06:58
Last Modified:28 Jan 2021 21:01
Publisher:Springer
ISSN:0179-7158
OA Status:Hybrid
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1007/s00066-020-01707-8
PubMed ID:33226469

Download

Hybrid Open Access

Download PDF  'Pretreatment central quality control for craniospinal irradiation in non-metastatic medulloblastoma : First experiences of the German radiotherapy quality control panel in the SIOP PNET5 MB trial'.
Preview
Content: Published Version
Filetype: PDF
Size: 741kB
View at publisher
Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)