Prospective use of ablation index for the ablation of right ventricle outflow tract premature ventricular contractions: a proof of concept study


Gasperetti, Alessio; Sicuso, Rita; Dello Russo, Antonio; Zucchelli, Giulio; Saguner, Ardan Muammer; Notarstefano, Pasquale; Soldati, Ezio; Bongiorni, Maria Grazia; Della Rocca, Domenico Giovanni; Mohanty, Sanghamitra; Carbucicchio, Corrado; Duru, Firat; Di Biase, Luigi; Natale, Andrea; Tondo, Claudio; Casella, Michela (2021). Prospective use of ablation index for the ablation of right ventricle outflow tract premature ventricular contractions: a proof of concept study. Europace, 23(1):91-98.

Abstract

AIMS

Radiofrequency catheter ablation (RFCA) represents an effective option for idiopathic premature ventricular contractions (PVCs) treatment. Ablation Index (AI) is a novel ablation marker incorporating RF power, contact force, and time of delivery into a single weighted formula. Data regarding AI-guided PVCs RFCA are currently lacking. Aim of the study was to compare AI-guided and standard RFCA outcomes in patients with PVCs originating from the right ventricle outflow tract (RVOT).

METHODS AND RESULTS

Consecutive patients undergoing AI-guided RFCA of RVOT idiopathic PVCs were prospectively enrolled. Radiofrequency catheter ablation was performed following per-protocol target cut-offs of AI, depending on targeted area (RVOT free wall AI cut-off: 590; RVOT septum AI cut-off: 610). A multi-centre cohort of propensity-matched (age, sex, ejection fraction, and PVC site) patients undergoing standard PVCs RFCA was used as a comparator. Sixty AI-guided patients (44.2 ± 18.0 years old, 58% male, left ventricular ejection fraction 56.2 ± 3.8%) were enrolled; 34 (57%) were ablated in RVOT septum and 26 (43%) patients in the RVOT free wall area. Propensity match with 60 non-AI-guided patients was performed. Acute outcomes and complications resulted comparable. At 6 months, arrhythmic recurrence was more common in non-AI-guided patients whether in general (28% vs. 7% P = 0.003) or by ablated area (RVOT free wall: 27% vs. 4%, P = 0.06; RVOT septum 29% vs. 9% P = 0.05). Ablation Index guidance was associated with improved survival from arrhythmic recurrence [overall odds ratio 6.61 (1.95-22.35), P = 0.001; RVOT septum 5.99 (1.21-29.65), P = 0.028; RVOT free wall 11.86 (1.12-124.78), P = 0.039].

CONCLUSION

Ablation Index-guidance in idiopathic PVCs ablation was associated with better arrhythmic outcomes at 6 months of follow-up.

Abstract

AIMS

Radiofrequency catheter ablation (RFCA) represents an effective option for idiopathic premature ventricular contractions (PVCs) treatment. Ablation Index (AI) is a novel ablation marker incorporating RF power, contact force, and time of delivery into a single weighted formula. Data regarding AI-guided PVCs RFCA are currently lacking. Aim of the study was to compare AI-guided and standard RFCA outcomes in patients with PVCs originating from the right ventricle outflow tract (RVOT).

METHODS AND RESULTS

Consecutive patients undergoing AI-guided RFCA of RVOT idiopathic PVCs were prospectively enrolled. Radiofrequency catheter ablation was performed following per-protocol target cut-offs of AI, depending on targeted area (RVOT free wall AI cut-off: 590; RVOT septum AI cut-off: 610). A multi-centre cohort of propensity-matched (age, sex, ejection fraction, and PVC site) patients undergoing standard PVCs RFCA was used as a comparator. Sixty AI-guided patients (44.2 ± 18.0 years old, 58% male, left ventricular ejection fraction 56.2 ± 3.8%) were enrolled; 34 (57%) were ablated in RVOT septum and 26 (43%) patients in the RVOT free wall area. Propensity match with 60 non-AI-guided patients was performed. Acute outcomes and complications resulted comparable. At 6 months, arrhythmic recurrence was more common in non-AI-guided patients whether in general (28% vs. 7% P = 0.003) or by ablated area (RVOT free wall: 27% vs. 4%, P = 0.06; RVOT septum 29% vs. 9% P = 0.05). Ablation Index guidance was associated with improved survival from arrhythmic recurrence [overall odds ratio 6.61 (1.95-22.35), P = 0.001; RVOT septum 5.99 (1.21-29.65), P = 0.028; RVOT free wall 11.86 (1.12-124.78), P = 0.039].

CONCLUSION

Ablation Index-guidance in idiopathic PVCs ablation was associated with better arrhythmic outcomes at 6 months of follow-up.

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, further contribution
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:27 January 2021
Deposited On:01 Feb 2021 17:01
Last Modified:02 Feb 2021 02:14
Publisher:Oxford University Press
ISSN:1099-5129
OA Status:Closed
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1093/europace/euaa228
PubMed ID:33063099

Download

Full text not available from this repository.
View at publisher

Get full-text in a library