Diagnosis of Periprosthetic Hip Joint Infection Using MRI with Metal Artifact Reduction at 1.5 T


Galley, Julien; Sutter, Reto; Stern, Christoph; Filli, Lukas; Rahm, Stefan; Pfirrmann, Christian W A (2020). Diagnosis of Periprosthetic Hip Joint Infection Using MRI with Metal Artifact Reduction at 1.5 T. Radiology, 296(1):98-108.

Abstract

Background MRI with metal artifact reduction has gained importance in assessment of pain with total hip arthroplasty (THA). However, its role in diagnosis of periprosthetic joint infection (PJI) has not been well defined. Purpose To evaluate findings of PJI after THA and to determine the diagnostic performance of 1.5-T MRI with metal artifact reduction. Materials and Methods Dedicated compressed sensing-based slice encoding for metal artifact correction 1.5-T MRI examinations (from January 2015 to April 2018) in patients with THA PJI (infection group) and noninfected THA (control group) were retrospectively evaluated by two musculoskeletal radiologists. Fisher exact test was used to compare the groups. Sensitivity, specificity, and accuracy were evaluated for each finding. Interobserver reliability was assessed with κ statistics. Results Forty patients (mean age, 69 years ± 11 [standard deviation]; 26 men) in the infection group and 100 patients (mean age, 67 years ± 11; 42 men) in the control group were evaluated. Periosteal reaction, capsule edema, and intramuscular edema differed between the two groups (P < .001 for each finding). Periosteal reaction was found in 31 of 40 patients with infection and 10 of 100 participants in the control group (sensitivity, 78%; specificity, 90%; accuracy, 86%); capsule edema was found in 33 of 40 (infection group) and five of 100 (control group) (sensitivity, 83%; specificity, 95%; accuracy, 91%); and intramuscular edema was found in 38 of 40 (infection group) and 14 of 100 (control group) (sensitivity, 95%; specificity, 86%; accuracy, 89%). Interobserver agreement was almost perfect, with κ values between 0.88 and 0.92. No difference between the two groups was found regarding the presence of osteolysis (infection group, 23 of 40; control group, 60 of 100), bone marrow edema (39 of 40 vs 87 of 100), effusion (20 of 40 vs 26 of 100), abductor tendon lesion (22 of 40 vs 62 of 100), or bursitis (14 of 40 vs 34 of 100) (P > .05 for each finding). Conclusion The presence of periosteal reaction, capsule edema, and intramuscular edema after total hip arthroplasty at 1.5-T MRI with metal artifact reduction had a high accuracy in evaluation of periprosthetic joint infection. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Zanetti in this issue.

Abstract

Background MRI with metal artifact reduction has gained importance in assessment of pain with total hip arthroplasty (THA). However, its role in diagnosis of periprosthetic joint infection (PJI) has not been well defined. Purpose To evaluate findings of PJI after THA and to determine the diagnostic performance of 1.5-T MRI with metal artifact reduction. Materials and Methods Dedicated compressed sensing-based slice encoding for metal artifact correction 1.5-T MRI examinations (from January 2015 to April 2018) in patients with THA PJI (infection group) and noninfected THA (control group) were retrospectively evaluated by two musculoskeletal radiologists. Fisher exact test was used to compare the groups. Sensitivity, specificity, and accuracy were evaluated for each finding. Interobserver reliability was assessed with κ statistics. Results Forty patients (mean age, 69 years ± 11 [standard deviation]; 26 men) in the infection group and 100 patients (mean age, 67 years ± 11; 42 men) in the control group were evaluated. Periosteal reaction, capsule edema, and intramuscular edema differed between the two groups (P < .001 for each finding). Periosteal reaction was found in 31 of 40 patients with infection and 10 of 100 participants in the control group (sensitivity, 78%; specificity, 90%; accuracy, 86%); capsule edema was found in 33 of 40 (infection group) and five of 100 (control group) (sensitivity, 83%; specificity, 95%; accuracy, 91%); and intramuscular edema was found in 38 of 40 (infection group) and 14 of 100 (control group) (sensitivity, 95%; specificity, 86%; accuracy, 89%). Interobserver agreement was almost perfect, with κ values between 0.88 and 0.92. No difference between the two groups was found regarding the presence of osteolysis (infection group, 23 of 40; control group, 60 of 100), bone marrow edema (39 of 40 vs 87 of 100), effusion (20 of 40 vs 26 of 100), abductor tendon lesion (22 of 40 vs 62 of 100), or bursitis (14 of 40 vs 34 of 100) (P > .05 for each finding). Conclusion The presence of periosteal reaction, capsule edema, and intramuscular edema after total hip arthroplasty at 1.5-T MRI with metal artifact reduction had a high accuracy in evaluation of periprosthetic joint infection. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Zanetti in this issue.

Statistics

Citations

Dimensions.ai Metrics
25 citations in Web of Science®
24 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

168 downloads since deposited on 05 Mar 2021
70 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Language:English
Date:July 2020
Deposited On:05 Mar 2021 09:29
Last Modified:27 Jan 2022 05:34
Publisher:Radiological Society of North America
ISSN:0033-8419
OA Status:Hybrid
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1148/radiol.2020191901
PubMed ID:32396046
  • Content: Published Version
  • Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)