Header

UZH-Logo

Maintenance Infos

Impact of design of coronary stents and length of dual antiplatelet therapies on ischaemic and bleeding events: a network meta-analysis of 64 randomized controlled trials and 102 735 patients


D'Ascenzo, Fabrizio; Iannaccone, Mario; Saint-Hilary, Gaelle; Bertaina, Maurizio; Schulz-Schüpke, Stefanie; Wahn Lee, Cheol; Chieffo, Alaide; Helft, Gerard; Gili, Sebastiano; Barbero, Umberto; Biondi Zoccai, Giuseppe; Moretti, Claudio; Ugo, Fabrizio; D'Amico, Maurizio; Garbo, Roberto; Stone, Gregg; Rettegno, Sara; Omedè, Pierluigi; Conrotto, Federico; Templin, Christian; Colombo, Antonio; Park, Seung-Jung; Kastrati, Adnan; Hildick-Smith, David; Gasparini, Mauro; Gaita, Fiorenzo (2017). Impact of design of coronary stents and length of dual antiplatelet therapies on ischaemic and bleeding events: a network meta-analysis of 64 randomized controlled trials and 102 735 patients. European Heart Journal, 38(42):3160-3172.

Abstract

Aims

The differential impact on ischaemic and bleeding events of the type of drug-eluting stent [durable polymer stents [DES] vs. biodegradable polymer stents vs. bioresorbable scaffolds (BRS)] and length of dual antiplatelet therapy (DAPT) remains to be defined.

Methods and results

Randomized controlled trials comparing different types of DES and/or DAPT durations were selected. The primary endpoint was Major Adverse Cardiovascular Events (MACE) [a composite of death, myocardial infarction (MI), and target vessel revascularization]. Definite stent thrombosis (ST) and single components of MACE were secondary endpoints. The arms of interest were: BRS with 12 months of DAPT (12mDAPT), biodegradable polymer stent with 12mDAPT, durable polymer stent [everolimus-eluting (EES), zotarolimus-eluting (ZES)] with 12mDAPT, EES/ZES with <12 months of DAPT, and EES/ZES with >12 months of DAPT (DAPT > 12 m). Sixty-four studies with 150 arms and 102 735 patients were included. After a median follow-up of 20 months, MACE rates were similar in the different arms of interest. EES/ZES with DAPT > 12 m reported a lower incidence of MI than the other groups, while BRS showed a higher rate of ST when compared to EES/ZES, irrespective of DAPT length. A higher risk of major bleedings was observed for DAPT > 12 m as compared to shorter DAPT.

Conclusion

Durable and biodegradable polymer stents along with BRS report a similar rate of MACE irrespective of DAPT length. Fewer MI are observed with EES/ZES with DAPT > 12 m, while a higher rate of ST is reported for BRS when compared to EES/ZES, independently from DAPT length. Stent type may partially affect the outcome together with DAPT length.

Abstract

Aims

The differential impact on ischaemic and bleeding events of the type of drug-eluting stent [durable polymer stents [DES] vs. biodegradable polymer stents vs. bioresorbable scaffolds (BRS)] and length of dual antiplatelet therapy (DAPT) remains to be defined.

Methods and results

Randomized controlled trials comparing different types of DES and/or DAPT durations were selected. The primary endpoint was Major Adverse Cardiovascular Events (MACE) [a composite of death, myocardial infarction (MI), and target vessel revascularization]. Definite stent thrombosis (ST) and single components of MACE were secondary endpoints. The arms of interest were: BRS with 12 months of DAPT (12mDAPT), biodegradable polymer stent with 12mDAPT, durable polymer stent [everolimus-eluting (EES), zotarolimus-eluting (ZES)] with 12mDAPT, EES/ZES with <12 months of DAPT, and EES/ZES with >12 months of DAPT (DAPT > 12 m). Sixty-four studies with 150 arms and 102 735 patients were included. After a median follow-up of 20 months, MACE rates were similar in the different arms of interest. EES/ZES with DAPT > 12 m reported a lower incidence of MI than the other groups, while BRS showed a higher rate of ST when compared to EES/ZES, irrespective of DAPT length. A higher risk of major bleedings was observed for DAPT > 12 m as compared to shorter DAPT.

Conclusion

Durable and biodegradable polymer stents along with BRS report a similar rate of MACE irrespective of DAPT length. Fewer MI are observed with EES/ZES with DAPT > 12 m, while a higher rate of ST is reported for BRS when compared to EES/ZES, independently from DAPT length. Stent type may partially affect the outcome together with DAPT length.

Statistics

Citations

Dimensions.ai Metrics
58 citations in Web of Science®
59 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 13 Sep 2021
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, further contribution
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:7 November 2017
Deposited On:13 Sep 2021 11:07
Last Modified:27 Jan 2022 07:47
Publisher:Oxford University Press
ISSN:0195-668X
OA Status:Closed
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1093/eurheartj/ehx437
PubMed ID:29020300