Minimally invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repair


Kempfert, J; Blumenstein, J; Chu, M W A; Pritzwald-Stegmann, P; Kobilke, T; Falk, V; Mohr, F W; Walther, T (2009). Minimally invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repair. European Journal of Cardio-Thoracic Surgery, 35(6):965-969.

Abstract

OBJECTIVE: Based upon recent developments in transcatheter technology, this study was designed to evaluate the feasibility and haemodynamic performance of transcatheter valve-in-a-ring (VinR) implantation for potentially failed mitral repair using a minimally invasive, transatrial, off-pump approach. METHODS: Adult sheep (54.3+/-3.0 kg) underwent mitral valve repair with a 26 mm complete annuloplasty ring (Physio) using standard conventional techniques. To simulate the redo operation, a transcatheter 23 mm pericardial prosthesis (Edwards Sapien) mounted on a balloon-inflatable steel stent was deployed within the annuloplasty ring. VinR implantation was performed off-pump under rapid pacing in four and on-pump in three animals using an antegrade transatrial approach under fluoroscopic guidance. RESULTS: Transcatheter VinR implantation was successful in all seven sheep. Mean transvalvular gradient was 4.9+/-0.3 mmHg. VinR function was excellent with no leak in one, good with mild leak in five (trans-stent: four, paravalvular: one) and sufficient with moderate central leak in one animal, respectively. Valve deployment required 10.0+/-0.7 min and all transcatheter prostheses were confirmed in good position on postmortem analysis, without any signs of valve dislocation or embolisation. In an in-vitro model, the minimum force required to dislodge the valve was 32.9+/-5.2N, which was well above the normal estimated forces generated by the left ventricle. One animal was kept alive to assess mid-term outcome and is still well 12 months after the VinR implantation. CONCLUSIONS: Transatrial, transcatheter mitral VinR implantation is feasible using a minimally invasive off-pump approach. VinR implantation is a promising concept for re-operative surgery for selected patients after failed mitral valve repair.

Abstract

OBJECTIVE: Based upon recent developments in transcatheter technology, this study was designed to evaluate the feasibility and haemodynamic performance of transcatheter valve-in-a-ring (VinR) implantation for potentially failed mitral repair using a minimally invasive, transatrial, off-pump approach. METHODS: Adult sheep (54.3+/-3.0 kg) underwent mitral valve repair with a 26 mm complete annuloplasty ring (Physio) using standard conventional techniques. To simulate the redo operation, a transcatheter 23 mm pericardial prosthesis (Edwards Sapien) mounted on a balloon-inflatable steel stent was deployed within the annuloplasty ring. VinR implantation was performed off-pump under rapid pacing in four and on-pump in three animals using an antegrade transatrial approach under fluoroscopic guidance. RESULTS: Transcatheter VinR implantation was successful in all seven sheep. Mean transvalvular gradient was 4.9+/-0.3 mmHg. VinR function was excellent with no leak in one, good with mild leak in five (trans-stent: four, paravalvular: one) and sufficient with moderate central leak in one animal, respectively. Valve deployment required 10.0+/-0.7 min and all transcatheter prostheses were confirmed in good position on postmortem analysis, without any signs of valve dislocation or embolisation. In an in-vitro model, the minimum force required to dislodge the valve was 32.9+/-5.2N, which was well above the normal estimated forces generated by the left ventricle. One animal was kept alive to assess mid-term outcome and is still well 12 months after the VinR implantation. CONCLUSIONS: Transatrial, transcatheter mitral VinR implantation is feasible using a minimally invasive off-pump approach. VinR implantation is a promising concept for re-operative surgery for selected patients after failed mitral valve repair.

Statistics

Citations

Dimensions.ai Metrics
42 citations in Web of Science®
44 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 29 Sep 2009
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiac Surgery
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Pulmonary and Respiratory Medicine
Health Sciences > Cardiology and Cardiovascular Medicine
Language:English
Date:2009
Deposited On:29 Sep 2009 13:10
Last Modified:03 Oct 2023 01:39
Publisher:Elsevier
ISSN:1010-7940
OA Status:Closed
Publisher DOI:https://doi.org/10.1016/j.ejcts.2009.02.018
PubMed ID:19328008