Header

UZH-Logo

Maintenance Infos

Improved quality tests of R11410-21 photomultiplier tubes for the XENONnT experiment


Antochi, V C; Baudis, L; Galloway, M; Cichon, D; Conrad, J; Ferella, A D; Hoetzsch, L; Kazama, S; Koltman, G; Landsman, H; Lindner, M; Mahlstedt, J; Marrodán Undagoitia, T; Pelssers, B; Wack, O; Wulf, J (2021). Improved quality tests of R11410-21 photomultiplier tubes for the XENONnT experiment. Journal of Instrumentation, 16(08):P08033.

Abstract

Photomultiplier tubes (PMTs) are often used in low-background particle physics experiments, which rely on an excellent response to single-photon signals and stable long-term operation. In particular, the Hamamatsu R11410 model is the light sensor of choice for liquid xenon dark matter experiments, including XENONnT. The same PMT model was also used for the predecessor, XENON1T, where issues affecting its long-term operation were observed. Here, we report on an improved PMT testing procedure which ensures optimal performance in XENONnT. Using both new and upgraded facilities, we tested 368 new PMTs in a cryogenic xenon environment. We developed new tests targeted at the detection of light emission and the degradation of the PMT vacuum through small leaks, which can lead to spurious signals known as afterpulses, both of which were observed in XENON1T. We exclude the use of 26 of the 368 tested PMTs and categorise the remainder according to their performance. Given that we have improved the testing procedure, yet we rejected fewer PMTs, we expect significantly better PMT performance in XENONnT.

Abstract

Photomultiplier tubes (PMTs) are often used in low-background particle physics experiments, which rely on an excellent response to single-photon signals and stable long-term operation. In particular, the Hamamatsu R11410 model is the light sensor of choice for liquid xenon dark matter experiments, including XENONnT. The same PMT model was also used for the predecessor, XENON1T, where issues affecting its long-term operation were observed. Here, we report on an improved PMT testing procedure which ensures optimal performance in XENONnT. Using both new and upgraded facilities, we tested 368 new PMTs in a cryogenic xenon environment. We developed new tests targeted at the detection of light emission and the degradation of the PMT vacuum through small leaks, which can lead to spurious signals known as afterpulses, both of which were observed in XENON1T. We exclude the use of 26 of the 368 tested PMTs and categorise the remainder according to their performance. Given that we have improved the testing procedure, yet we rejected fewer PMTs, we expect significantly better PMT performance in XENONnT.

Statistics

Citations

Dimensions.ai Metrics
8 citations in Web of Science®
12 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

38 downloads since deposited on 23 Dec 2021
10 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:07 Faculty of Science > Physics Institute
Dewey Decimal Classification:530 Physics
Scopus Subject Areas:Physical Sciences > Mathematical Physics
Physical Sciences > Instrumentation
Uncontrolled Keywords:Mathematical Physics, Instrumentation
Language:English
Date:1 August 2021
Deposited On:23 Dec 2021 06:21
Last Modified:27 Nov 2023 02:40
Publisher:IOP Publishing
ISSN:1748-0221
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1088/1748-0221/16/08/p08033
  • Content: Published Version
  • Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)